Just another in a long list of questions I will be asking as I setup my WMO system:
I am going to heat the oil before I filter it but I am not sure what size water heater elements to get. How are you guys sizing your heating elements? I was planning on running two elements at about 1/3 and 2/3 up the side of a 55 gallon drum. Also, are you just sticking the element into the oil or is it inside a thermowell so it doesn't touch the oil. I have clean new drums that I plan to weld in bungs for the elements.
__________________
M35A2 (down but not out)
M715
M105A2 M101A3 M1102
MEP0016D 3kw
M1009
FYI they make drum heater, but to answer, mine are exposed to the directly. at one time I used an ol water heater
__________________
Nothing in this world is as useless as a man in flip flops....
1028 with NV4500 swap
1009 turbo,700r4 with a/c
M35a2 filter mod and 2 flat tires
m37 with 6.2 and nv4500 with 14 bolt and 60 axle in progress
You have to submerge the elements in a liquid- otherwise they burn out in short order.
An old electric water heater works dang near perfect. I would flip it so you have the dome at the bottom, to act as a better drain than what's on a water heater normally. Look for one with the safety in the middle of the top.
__________________ And when at last he came upon the vehicle, he perceived the distress of the engine therein and forthwith struck it with a hammer and it was good. Thereupon the engine ignited and was filled with strength...
1985 M1008 w/'hyrail' gear, EX-Ft Stewart Railroad
1983 M915a1 'Rosie'
1980 MKT-75A
1979 M967 Refueling tanker
1970 M818 'Boxer' aka M818 of DEATH
1969 40ft USA Boxcar in OD green
1968 M101
1968 M270
1967 M543 'Becka tha Wrecka'
1953 60ft Troop Train Kitchen car
1953 60ft 8 room Domitory car
1929 Plymouth 10 ton gas loco, EX-USN
My plans are to heat and let it settle, then go through several levels of filtration. The filtration will be an assortment of oil and water filters that get it down to at least 5 micron. If the WMO works well, I will get a centrifuge.
__________________
M35A2 (down but not out)
M715
M105A2 M101A3 M1102
MEP0016D 3kw
M1009
I will be on the lookout for a used water heater! I looked over the Wolverine site and was trying to make sure that I could heat the oil up to 160 if/when I go to the centrifuge. I saw some pretty slick drum heaters, but just didn't see any in my price range for a test setup like I am running. If this turns into a long term operation I will definitely get an adjustable drum heater.
__________________
M35A2 (down but not out)
M715
M105A2 M101A3 M1102
MEP0016D 3kw
M1009