» Online Users: 406
123 members and 283 guests
06streetrod
,
123mack
,
2buells
,
2dogsafightin
,
2ndchance
,
3dAngus
,
6869704x4
,
73m819
,
Amram
,
Atwater
,
backroads
,
bdziec
,
bigmatt
,
bigugh20
,
Bikesdestroy
,
BillF
,
Bob H
,
boonedoggy
,
Brutusdog
,
butch atkins
,
buzzairborne
,
cajun666
,
Castle Bravo
,
chvss65
,
Clayshootr
,
combst32
,
countryboy67
,
cpf240
,
crazywelder72
,
Csm Davis
,
cucv1833
,
CycleJay
,
Danger Ranger
,
dangerfieldinc
,
DAP
,
dezert ratt
,
DieselInfantry711
,
Dieselking22
,
DKELONE
,
dpsmith
,
Driver523
,
Durango_USMC
,
Evil Dr. Porkchop
,
Feelin_froggy
,
finnd1
,
flyxpl
,
fordgasmz
,
G749
,
goliath
,
gpp111
,
grimus
,
gringeltaube
,
groundog
,
Hot Duck
,
Ironhorse
,
ITeach2Wheels
,
ivbeenrokd
,
j3ffw23
,
jaxsof
,
JB
,
Jeff Nelson
,
jimmy-90
,
johnejones
,
KC2WCQ
,
keith648356
,
kennys@wi.rr.com
,
Lapua Dan
,
llong66
,
Lonesome715
,
LV2XLR8
,
mactiredearg
,
maddawg308
,
marchplumber
,
MichiganMudder
,
MidNightRider
,
Monkey Man
,
MT4222
,
nw42
,
ODdave
,
oddave715
,
patracy
,
pegasus55
,
ranger.41
,
Recovry4x4
,
RedHeadTarn
,
redneck rebel
,
Repo3004
,
rhud33
,
rjinga
,
robertss
,
sandcobra164
,
Scooteerr
,
scoutmanadam
,
Sephirothq
,
sigo
,
SMOKEWAGON66
,
SouthernSteel
,
Stalwart
,
steelsoldiers
,
Stonepicker1
,
tamecrow
,
Terracoma
,
tigger
,
tjm
,
TURKEY131
,
tvguy
,
Tweeter166
,
uscgmatt
,
Vfflang
,
Vistage
,
voivod
,
VP17IFT
,
walkerhunter
,
WantOne
,
Welder Sam
,
wkbrdngsnw
,
Woodsplinter
,
zebedee
,
zeisshensoldt
,
zyrtecx
Most users ever online was 902, 10-29-2011 at 04:09.
10-14-2006, 15:09
#1 (permalink )
4 Star General
Join Date: Oct 2005
Location: Dexter, MI
Posts: 4,126
Help with slave cable receptacle attachment on 10k Gen
I am getting around to seeing if my gens start. I am robbing the starter off one to put on the other. When I removed the starter from the one I saw that the Slave Cable Connector positive was attached to the starter connection of the starter solenoid. I would think it should be on the battery side of the solenoid. If I was to connect the slave cable I think it would cause the starter to engage until the slave cable is removed. Can someone look at their starter connections and let me know how their slave cable connector is attached at the starter solenoid? Please let know something. I have checked all the related TMs and it does not show the wiring of the connector.
__________________
Chuck Graham
1969 Kaiser-Jeep M35A2
10-14-2006, 15:36
#2 (permalink )
Fleet Admiral/Moderator
Join Date: Jun 2004
Location: Loxahatchee, FL
Posts: 21,808
RE: Help with slave cable receptacle attachment on 10k Gen
It goes on the lug of the solenoid farthest from the starter.
__________________
Arm yourself with the sword of knowledge, read the TMs.
http://www.steelsoldiers.com/technical-manuals/
This Steel Soldier Honors the Living Memory of David Frankenhauser, 1954-2009.
May you Sail in the Grace of Our Lord, Chaplain!
“The earnest prayer of a righteous person has great power and produces wonderful results.” James 5:16.
10-14-2006, 17:53
#3 (permalink )
4 Star General
Join Date: Oct 2005
Location: Dexter, MI
Posts: 4,126
RE: Help with slave cable receptacle attachment on 10k Gen
GI must have put it on wrong.
__________________
Chuck Graham
1969 Kaiser-Jeep M35A2
Posting Rules