I have been using my MEP 002A heavily for the last 3 days due to a primary genset failure. I am offgrid at an oil field.
Yesterday evening, I needed to refuel the MEP 002A and it seemed to wind down slowly when the master switch was set to off.
Just a few minutes ago, I needed to refuel again and it took a good 2 minutes for the generator to finally shut off. The final 30 seconds of runtime were just barely turning over. Pulling the emergency shut off switch had no effect.
The engine shuts off by the solenoid pushing the control lever down, over-riding the governor's spring. Either the spring link is dirty or the solenoid's spring force is weak. Either way, spray some Berryman B12 over the spring link (telescoping link between governor arm and injection pump control lever) and over the control lever to injection pump. This gets dirty, it needs to be clean.
You can shut them down by manually pushing down on the control lever. If the solenoid spring is weak, Generator Parts
And for hot refuel, get a hose with flare fittings and use the Aux. Fuel switch position. If you get the complete remote fuel setup, you can run off a 55 gallon drum for 4 days between fuelings and oil changes
The Following User Says Thank You to Keith_J For This Useful Post:
I have seen the shutoff solenoid mounting screws back off on several occasions; I put red loctite on all of the ones I work on.
The plunger on the solenoid has an adjustable pushrod; I have also seen those back off and not completely shut down the set.
__________________
71 M35A2: 395's, flatbed, LED lighting, water/meth injection, full hydro, etc.
01 Dodge Ram 5.9: Fast. Real fast.
90 Samurai: onboard air, toyota PS, lockers, 6.5 tcase, Warn 9.5XP etc.
00 Vitara: Unimog 404 axles, air lockers, 4 link, full hydro, W56 tranny, dual cases, 40" pitbull rockers with Stauns, work in progress
01 XJ: Ford 8.8" w/ Ected locker, lock right front, 4.56 gears, SYE kit, custom bumpers, sliders, onboard air, etc.
Lots of MEP's
One very understanding wife
The Following User Says Thank You to sewerzuk For This Useful Post:
Thanks guys! Light pressure on the control lever induced the solenoid to operate properly. The entire linkage does need a general cleaning. In the meantime, it is out there chigging away doing what generators do best. I appreciate the help.
Also common is for the solenoid to not move the lever to the on position if the linkage is dirty. If the genset ever fails to start within a reasonable time, make sure the linkage isn't keeping the fuel shut off.
__________________
Gary
US Army 1970-1971 MOS: 11D20
USAR 1972-1973
MVPA: #32652
1998 AM General M35A3 W/W M66 Gun Ring
1969 Kaiser Jeep M35A2 W/W
2000 M149A2 (USMC) Water Buffalo
1968 Johnson M105A2
1992 M116A2 Trailer Mounted MEP-003A Gen Set
30D36R 3 KW Gen Set ex-NC ANG
The Following User Says Thank You to glcaines For This Useful Post:
Dumb question, why are you shutting it down to refuel? Even if you are not using the built in aux. fuel set-up, you will do no damage to the set if you just open the fuel cap and refuel it while it's running.
__________________
Haspin 2011 Quotes...
Gimp, would you stop nuttin on my husband?---"westechs_wifey"
Anything can be used as a suppository, as long as it has one rounded edge---"doghead"
I don't care if you're gay, just don't shove it down my throat!---"Kipman"
Get a wheel!!!---"gimpyrobb"
Even a blind squirrel finds an acorn every now and then!
1970 M35A2 "The Stone Wagon"
MEP-003a 3000 hrs
MEP-003a 1500 hrs
MEP-002a & MEP-003a Spin-on oil filter kits are still 4 sale, PM me for details
Dumb question, why are you shutting it down to refuel? Even if you are not using the built in aux. fuel set-up, you will do no damage to the set if you just open the fuel cap and refuel it while it's running.
It is sitting in an M101A2 with the top on. It is way toooooo loud to get inside with the unit running. I also check oil levels and for any leaks while it is shut off.
It is sitting in an M101A2 with the top on. It is way toooooo loud to get inside with the unit running. I also check oil levels and for any leaks while it is shut off.
Good enough reason. I just couldn't think of a need for shutting it down. Once you trust your set to not leak oil and fuel, you'll just put some ear plugs in and go in there and re-fuel it while running.
__________________
Haspin 2011 Quotes...
Gimp, would you stop nuttin on my husband?---"westechs_wifey"
Anything can be used as a suppository, as long as it has one rounded edge---"doghead"
I don't care if you're gay, just don't shove it down my throat!---"Kipman"
Get a wheel!!!---"gimpyrobb"
Even a blind squirrel finds an acorn every now and then!
1970 M35A2 "The Stone Wagon"
MEP-003a 3000 hrs
MEP-003a 1500 hrs
MEP-002a & MEP-003a Spin-on oil filter kits are still 4 sale, PM me for details
The Following User Says Thank You to Speddmon For This Useful Post: