I had contacted some manufacturers of filters I use. I am posting in case it might help anyone.

Hastings filters FF906 and FF973 are 4 micron nominal and 15 micron absolute. Those are the primary and secondary filters for stock deuces.

I have also used Fleetguard FS1000 and FF211.

This is the specs I got from Cummins on the FS1000:
FILTRATION, MECHANICAL SPECIFICATIONS AND TEST STANDARDS



CAPACITY 72 g CECO ES14225

TERMINAL DP 7.97 in Hg

RATED FLOW 89.83 GPH

CLEAN ELEMENT DP, MAX 1 in Hg CECO ES14225

EFFICIENCY, TWA BY SAE J 1985 98.7 % SAE J1985

MICRON RATING BY SAE J 1985 10 micron SAE J1985

EFFICIENCY, TWA @ 2ND POINT BY 83 % SAE J1985

SAE J 1985

MICRON SIZE @ 2ND POINT BY 5 micron SAE J1985

SAE J 1985

EMULSIFIED WATER SEPARATION 95 % SAE J1488

FREE WATER SEPARATION 95 % SAE J1839

ELEMENT COLLAPSE/BURST, MIN 39.88 PSI CECO ES14225

HYDROSTATIC BURST, MIN 203.05 PSI ISO 4548-6

HYDR. PULSE DURABILITY, MIN 41000 Cycles CECO ES14225

AT HIGH PRESSURE 101.52 PSI

AT PULSE FREQUENCY 4 Hz



SINUSOIDAL VIBRATION, MIN 1000000 Cycles CECO ES14225

AT ACCELERATION 5.1 G's

HIGH TEMP 250 F°

LOW TEMP -45 F°

This is for the FF211:
FILTRATION, MECHANICAL SPECIFICATIONS AND TEST STANDARDS



CAPACITY 52 g SAE J905

TERMINAL DP 7.97 in Hg

RATED FLOW 120.21 GPH

CLEAN ELEMENT DP, MAX 1.48 in Hg SAE J905

EFFICIENCY, TWA BY SAE J 1985 97 % SAE J1985

MICRON RATING BY SAE J 1985 8 micron SAE J1985

EFFICIENCY, TWA @ 2ND POINT BY 90.4 % SAE J1985

SAE J 1985

MICRON SIZE @ 2ND POINT BY 5 micron SAE J1985

SAE J 1985

ELEMENT COLLAPSE/BURST, MIN 79.77 PSI ISO 4020/1

HYDROSTATIC BURST, MIN 203.05 PSI ISO 4548-6

HYDR. PULSE DURABILITY, MIN 50000 Cycles ISO 4548-5

AT HIGH PRESSURE 101.52 PSI

SINUSOIDAL VIBRATION, MIN 10000000 Cycles ISO 4548-7







AT ACCELERATION 5.1 G's

HIGH TEMP 250 F°

LOW TEMP -45 F°
 

gimpyrobb

dumpsterlandingfromorbit!
27,785
747
113
Location
Cincy Ohio
These are just the ones I have been useing. In contacting customer service at most filter companys, I have been emailed LOTS of specs. I mistakenly deleted the info I got from Baldwin.
 
Top
AdBlock Detected

We get it, advertisements are annoying!

Sure, ad-blocking software does a great job at blocking ads, but it also blocks useful features of our website like our supporting vendors. Their ads help keep Steel Soldiers going. Please consider disabling your ad blockers for the site. Thanks!

I've Disabled AdBlock
No Thanks