Tab Content
  • KLChurch's Avatar
    10-17-2019, 19:42
    KLChurch replied to a thread MEP-004A, No output in Generators
    So I guess I will connect the single phase transformer to test the load test. I will try to find a dryer or oven at the appliance junk yard. Kris
    659 replies | 7829 view(s)
  • KLChurch's Avatar
    10-16-2019, 23:24
    KLChurch replied to a thread MEP-004A, No output in Generators
    Chainbreaker, Don't know your real name but your safety should be shouted fiercely like you have been doing. I have been very afraid of the power of...
    659 replies | 7829 view(s)
  • KLChurch's Avatar
    10-16-2019, 19:14
    KLChurch replied to a thread MEP-004A, No output in Generators
    BTW the sun finally came out and in the front of the gen was dry so there was no puddles Kris
    659 replies | 7829 view(s)
  • KLChurch's Avatar
    10-16-2019, 19:10
    KLChurch replied to a thread MEP-004A, No output in Generators
    Started the gen up. Started immediately and faster than ever before. The hz gage and volt gage seemed to be a little more stable ?????? why? The...
    659 replies | 7829 view(s)
  • KLChurch's Avatar
    10-16-2019, 18:03
    KLChurch replied to a thread MEP-004A, No output in Generators
    Ha Ha Ha. My mentor said patience is a virtue. Buzzards say patience my ass I'm going to kill something. Kris
    659 replies | 7829 view(s)
  • KLChurch's Avatar
    10-16-2019, 17:03
    KLChurch replied to a thread MEP-004A, No output in Generators
    Starter is installed and gen is ready to start, but after the rain settles down. Kris
    659 replies | 7829 view(s)
  • KLChurch's Avatar
    10-16-2019, 15:02
    KLChurch replied to a thread MEP-004A, No output in Generators
    Even though the starter seems to be easy to uninstall and install because it is there just looking at you, conventional sockets don't fit. They are...
    659 replies | 7829 view(s)
  • KLChurch's Avatar
    10-15-2019, 16:00
    KLChurch replied to a thread MEP-004A, No output in Generators
    Update: Received back the frequency transducer and starter today. I asked the starter repairman why the starter in his opinion failed. His...
    659 replies | 7829 view(s)
  • KLChurch's Avatar
    10-12-2019, 18:22
    KLChurch replied to a thread MEP-004A, No output in Generators
    During the mid 70's to the bottom 90's Analogue controlled metal cutting machines (NC) were more accurate than the CNC machines. This is because...
    659 replies | 7829 view(s)
  • KLChurch's Avatar
    10-11-2019, 15:40
    KLChurch replied to a thread MEP-004A, No output in Generators
    Update on starter: There was a lot of things wrong with it which I cant repeat because I don't understand the slang. A commentator needs to be...
    659 replies | 7829 view(s)
  • KLChurch's Avatar
    10-11-2019, 11:17
    KLChurch replied to a thread MEP-004A, No output in Generators
    So the engine would have to vary 30 RPM if the gages were good. I did not hear varying RPM.
    659 replies | 7829 view(s)
  • KLChurch's Avatar
    10-10-2019, 19:29
    KLChurch replied to a thread MEP-004A, No output in Generators
    Guy, Peter tested the Frequency Transducer and determined that it was OK. But the gages on the control panel are varying. 59 to 60 hz and 208 t0...
    659 replies | 7829 view(s)
  • KLChurch's Avatar
    10-09-2019, 19:09
    KLChurch replied to a thread MEP-004A, No output in Generators
    :beer: The Pilsner of Texas
    659 replies | 7829 view(s)
  • KLChurch's Avatar
    10-09-2019, 14:11
    KLChurch replied to a thread MEP-004A, No output in Generators
    The person at the shop was an old fart and remembered this starter. He also said it was a popular starter. He gave me a timeline of 2 to 3 days....
    659 replies | 7829 view(s)
  • KLChurch's Avatar
    10-09-2019, 12:05
    KLChurch replied to a thread MEP-004A, No output in Generators
    This is the starter tag
    659 replies | 7829 view(s)
  • KLChurch's Avatar
    10-08-2019, 18:02
    KLChurch replied to a thread MEP-004A, No output in Generators
    WoW, I want one of those. Novelty and a HOOT. Kris
    659 replies | 7829 view(s)
  • KLChurch's Avatar
    10-08-2019, 17:43
    KLChurch replied to a thread MEP-004A, No output in Generators
    Shipped the frequency whatever to Peter. He should have it Thursday. Next is to remove the starter. I should have it at the shop tomorrow. Kris
    659 replies | 7829 view(s)
  • KLChurch's Avatar
    10-08-2019, 17:23
    KLChurch replied to a thread MEP-004A, No output in Generators
    Guy, Is that a Pilsner Beer? My dad liked German Pilsners Kris
    659 replies | 7829 view(s)
  • KLChurch's Avatar
    10-08-2019, 15:30
    KLChurch replied to a thread MEP-004A, No output in Generators
    I found a Starter repair shop 15 miles away. They say they may be able to repair if needed and only if they can find repair parts. Does anyone...
    659 replies | 7829 view(s)
  • KLChurch's Avatar
    10-08-2019, 13:22
    KLChurch replied to a thread MEP-004A, No output in Generators
    Got some bad news. Tried to start the gen and would not crank the engine. The Amp gage showed a lot of discharge. Also the starter would not turn...
    659 replies | 7829 view(s)
  • KLChurch's Avatar
    10-08-2019, 12:30
    KLChurch replied to a thread MEP-004A, No output in Generators
    Very good info about the batteries. I have been considering a solar cell trickle system so I don't have an extension cord or remember to plug it in....
    659 replies | 7829 view(s)
  • KLChurch's Avatar
    10-07-2019, 21:39
    KLChurch replied to a thread MEP-004A, No output in Generators
    Coug That's good to know. Ive been texting Peter trying to trouble shoot the gen on Volts and hertz. I will report the results in the morn because...
    659 replies | 7829 view(s)
  • KLChurch's Avatar
    10-07-2019, 16:20
    KLChurch replied to a thread MEP-004A, No output in Generators
    :doghead:I'll raise my hand when I make a mistake and even higher on a dumb mistake. Kris
    659 replies | 7829 view(s)
  • KLChurch's Avatar
    10-07-2019, 15:45
    KLChurch replied to a thread MEP-004A, No output in Generators
    I guess I'm the confused. Their is an auto detected option on the tester. When I turned it to volts instead of muli volts the auto detect turned...
    659 replies | 7829 view(s)
  • KLChurch's Avatar
    10-07-2019, 15:11
    KLChurch replied to a thread MEP-004A, No output in Generators
    Guy I checked the DMM with a AAA battery and it said 1.559 dc volts Ill try disconnecting the two large wires and see if the DMM is getting...
    659 replies | 7829 view(s)
  • KLChurch's Avatar
    10-07-2019, 15:04
    KLChurch replied to a thread MEP-004A, No output in Generators
    That is where I'm checking it. My analogue is showing approx. 26 volts maybe a little higher. But my DMM is showing .O.L Kris
    659 replies | 7829 view(s)
  • KLChurch's Avatar
    10-07-2019, 14:25
    KLChurch replied to a thread MEP-004A, No output in Generators
    I checked the batteries while installed. Red on red, black on black. (Outputs to starter) No DC volts with the Dmm. What I'm I doing wrong? Kris...
    659 replies | 7829 view(s)
  • KLChurch's Avatar
    10-07-2019, 14:02
    KLChurch replied to a thread MEP-004A, No output in Generators
    Update: Charged the batteries separately. One started at 90% full and the other 95%. Took only a couple of mins at fast charge. (12 amps) Then...
    659 replies | 7829 view(s)
  • KLChurch's Avatar
    10-07-2019, 10:54
    KLChurch replied to a thread MEP-004A, No output in Generators
    Assuming is defined as "Ass You Me" My mentor reminded me of that when I was in my 20s Finally a cold front will be here today. So the temp will...
    659 replies | 7829 view(s)
  • KLChurch's Avatar
    10-06-2019, 19:41
    KLChurch replied to a thread MEP-004A, No output in Generators
    Purchased these batteries and installed. Had to take the battery tray out because it was too small. For some reason they are 1125 cranking amps...
    659 replies | 7829 view(s)
More Activity
About KLChurch

Basic Information

About KLChurch
Biography:
Oil Field Threads of Tubular Products since 1974
Location:
Montgomery/TX
Interests:
No real hobbies
Occupation:
Manager of Engineering

Signature


Murphy is my friend

Statistics


Total Posts
Total Posts
459
Posts Per Day
0.20
Total Thanks
Total Thanks
196
General Information
Last Activity
Yesterday 10:55
Join Date
08-28-2013
Referrals
0
iTrader Profile Recent Ratings
Feedback Score:
Positive Feedback:
0
0%
Members who left positive:
Members who left negative:
0
0
Total positive feedback: 0
Submit Feedback For KLChurch
View Complete Feedbacks for KLChurch
  Past
Month
Past
6 Months
Past
12 Months
  0 0 0
  0 0 0
  0 0 0