    11-10-2019, 20:32
    KLChurch replied to a thread MEP-004A, No output in Generators
    Also I want to include an update of the starting of the gen. It fires up immediately every time I try to start it. I have not been disconnecting the...
    685 replies | 9089 view(s)
  • KLChurch's Avatar
    11-10-2019, 19:28
    KLChurch replied to a thread MEP-004A, No output in Generators
    Update, uninstalling the float was a back breaker and half of the screws you cant see. You have to use a stubby flat head screw driver because of...
    685 replies | 9089 view(s)
  • KLChurch's Avatar
    11-03-2019, 20:34
    KLChurch replied to a thread MEP-004A, No output in Generators
    Update Had to prepare for a family reunion. I was hosting. (someone gave me Cuban cigars, man they were smooth) Plus I actually had to work for...
    685 replies | 9089 view(s)
  • KLChurch's Avatar
    10-31-2019, 18:51
    KLChurch replied to a thread MEP-004A, No output in Generators
    The weather here is now is in the 50's and 60's . So I don't expect the gen to get hot. Will be connecting more units to get a higher load. Trick...
    685 replies | 9089 view(s)
  • KLChurch's Avatar
    10-30-2019, 18:01
    KLChurch replied to a thread MEP-004A, No output in Generators
    Discovered the oven is totally gas. I might be able to connect a hot water heater that I have. I can connect several 110 units to increase the...
    685 replies | 9089 view(s)
  • KLChurch's Avatar
    10-30-2019, 12:14
    KLChurch replied to a thread MEP-004A, No output in Generators
    Ok, I will make a 2 hour run. The dryer shuts off after an hour. So I will run the dryer twice. Then I will make another two hour run. The...
    685 replies | 9089 view(s)
  • KLChurch's Avatar
    10-28-2019, 23:09
    KLChurch replied to a thread MEP-004A, No output in Generators
    Started the gen and ran the dryer for over a hour. Had to adjust the hz twice and volts once. (not very much) After I shut down the dryer the hz...
    685 replies | 9089 view(s)
  • KLChurch's Avatar
    10-28-2019, 18:40
    KLChurch replied to a thread MEP-004A, No output in Generators
    Guy That's what I was thinking but I was told not to connect L0 to anything. Just connect the transformer ground to the frame and the frame to the...
    685 replies | 9089 view(s)
  • KLChurch's Avatar
    10-28-2019, 16:09
    KLChurch replied to a thread MEP-004A, No output in Generators
    This was finished today. Connected a breaker box to transformer. Connected a dryer to breaker box. Lastly one of my pet deer's. (you have to zoom...
    685 replies | 9089 view(s)
  • KLChurch's Avatar
    10-28-2019, 16:01
    KLChurch replied to a thread MEP-004A, No output in Generators
    This s the connection from gen to transformer
    685 replies | 9089 view(s)
  • KLChurch's Avatar
    10-21-2019, 19:01
    KLChurch replied to a thread MEP-004A, No output in Generators
    I have two test subjects. A dryer and oven. (maybe 60 amps total. Haven't checked the tags) Had to get my tractor running this weekend to move...
    685 replies | 9089 view(s)
  • KLChurch's Avatar
    10-17-2019, 19:42
    KLChurch replied to a thread MEP-004A, No output in Generators
    So I guess I will connect the single phase transformer to test the load test. I will try to find a dryer or oven at the appliance junk yard. Kris
    685 replies | 9089 view(s)
  • KLChurch's Avatar
    10-16-2019, 23:24
    KLChurch replied to a thread MEP-004A, No output in Generators
    Chainbreaker, Don't know your real name but your safety should be shouted fiercely like you have been doing. I have been very afraid of the power of...
    685 replies | 9089 view(s)
  • KLChurch's Avatar
    10-16-2019, 19:14
    KLChurch replied to a thread MEP-004A, No output in Generators
    BTW the sun finally came out and in the front of the gen was dry so there was no puddles Kris
    685 replies | 9089 view(s)
  • KLChurch's Avatar
    10-16-2019, 19:10
    KLChurch replied to a thread MEP-004A, No output in Generators
    Started the gen up. Started immediately and faster than ever before. The hz gage and volt gage seemed to be a little more stable ?????? why? The...
    685 replies | 9089 view(s)
  • KLChurch's Avatar
    10-16-2019, 18:03
    KLChurch replied to a thread MEP-004A, No output in Generators
    Ha Ha Ha. My mentor said patience is a virtue. Buzzards say patience my ass I'm going to kill something. Kris
    685 replies | 9089 view(s)
  • KLChurch's Avatar
    10-16-2019, 17:03
    KLChurch replied to a thread MEP-004A, No output in Generators
    Starter is installed and gen is ready to start, but after the rain settles down. Kris
    685 replies | 9089 view(s)
  • KLChurch's Avatar
    10-16-2019, 15:02
    KLChurch replied to a thread MEP-004A, No output in Generators
    Even though the starter seems to be easy to uninstall and install because it is there just looking at you, conventional sockets don't fit. They are...
    685 replies | 9089 view(s)
  • KLChurch's Avatar
    10-15-2019, 16:00
    KLChurch replied to a thread MEP-004A, No output in Generators
    Update: Received back the frequency transducer and starter today. I asked the starter repairman why the starter in his opinion failed. His...
    685 replies | 9089 view(s)
No More Results
About KLChurch

Basic Information

About KLChurch
Biography:
Oil Field Threads of Tubular Products since 1974
Location:
Montgomery/TX
Interests:
No real hobbies
Occupation:
Manager of Engineering

Signature


Murphy is my friend

Statistics


Total Posts
Total Posts
470
Posts Per Day
0.21
Total Thanks
Total Thanks
205
General Information
Last Activity
11-11-2019 11:32
Join Date
08-28-2013
Referrals
0
iTrader Profile Recent Ratings
Feedback Score:
Positive Feedback:
0
0%
Members who left positive:
Members who left negative:
0
0
Total positive feedback: 0
Submit Feedback For KLChurch
View Complete Feedbacks for KLChurch
  Past
Month
Past
6 Months
Past
12 Months
  0 0 0
  0 0 0
  0 0 0