  1. tbar123

    Air horn woes

    My previous post was just the wires from the tester no circuit involved. That's why I believe my tester may be faulty. THe tester wires shouldn't change ohms by that much should they?
  2. tbar123

    Air horn woes

    Alright, I did the test that doghead suggested and something seemed weird with my ohm tester, So I put the 2 leads together and 1.8 So that was alright. So I took them apart for about 5 seconds reconnected them and it was 7. did it again and what do ya know 15 something. So I can't rely on this...
  3. tbar123

    Air horn woes

    New results in. I removed 25 from the solenoid-no horn I removed the horn switch case-horn still blows I tested for continuity between horn button wire,column case and all 4 switch mounting holes-none I tested the ground wire inside the switch for continuity-none I thought maybe the column was...
  4. tbar123

    Air horn woes

    I never thought of that! Test #3 for the day!
  5. tbar123

    Air horn woes

    I also put the old horn switch on the new column and I still have the same problem.
  6. tbar123

    Air horn woes

    THe second test I plan to run today is take the box off of the steering column horn switch and then see if the horn still blows. If it does then the cover isn't making contact, if it does fix it then it is making contact and I'll have to fix that.
  7. tbar123

    Air horn woes

    I checked both steering columns for continuity and both check out to be good.
  8. tbar123

    Air horn woes

    Doghead, I've removed every ground (1 at a time) except 25 the wire to the solenoid and the horn continues to blow.The only wire that will stop the horn is disconnecting 25 from the horn switch located at the bottom of the steering column.
  9. tbar123

    Air horn woes

    I'll try that after Mom gets out of bed! I think she'd kill me if I started blaring those horns when she's in bed!
  10. tbar123

    Air horn woes

    I'm not sure, 25 was connected to the solenoid,and 25A ground to the firewall was disconnected.
  11. tbar123

    Air horn woes

    No it does not, I tried that when I was jumping the wire. When the horns started to blow I disconnected the ground and the horns continued to blow.
  12. tbar123

    What have you done to your HEMTT/PLS/MK48 this week

    Could someone with one of these awesome machines be kind enough to take a picture of the front strut assembly. I'm trying to confirm the assembly I have is for these trucks. Thanks in advance.
  13. tbar123

    Air horn woes

    Your good Cape, I do appreciate any advice, because I'm completely stumped on this. Here is a few pics of the wires I jumped.I suppose pic 2 is the diode. Pic 1 is where 25 and 25A split.
  14. tbar123

    Air horn woes

    When the battery is turned off the horns stop. I have taken all four screws loose on the horn switch box(1 at a time) to see if those were grounding. No change every time the battery is turned on the horns blow!
  15. tbar123

    Air horn woes

    It doesn't matter what I do the horn will not stop blowing. I had the diode jumped and was expecting that to be it. Once the horn started to blow, I removed the jumper wire which I thought the cercuit would've been cut at that point, but No it just kept blowing. I'll add picks in the morning. I...
  16. tbar123

    Air horn woes

    Here is what I did over the past few hours, Not being a patient man I went out before the responses! Probably a bad idea. I disconnected the fusible link what it looks like to me. I then checked the ohms and of course my meter is going hay wire. So i made a jumper cable and the horn at 60 psi...
  17. tbar123

    Air horn woes

    Could I bypass it for testing then replace if burnt? Or would that cause major electrical issues? Than Juan and 74M35A2
  18. tbar123

    Air horn woes

    I looked through the TM's again and they don't have a fix for my problem. Now the horn won't shut off.Everytime the truck reaches 60psi the horns start to blair. Anyone have any ideas? Thanks in advance.
  19. tbar123

    Air horn woes

    My latest part should be in today. But could someone please tell me first shore on a working horn solenoid what side does circuit 26 go into, thank you
  20. tbar123

    M978 - Wildland Tactical Water Tender Conversion

    Awesome! Glad to see a used truck go back to work for a great cause!