Search results

  1. B

    Anyone in New Jersey want 2 cheap M103 trailers?

    they are air over hydraulic. I tow them with my half ton all the time. No need to cage the brakes
  2. B

    Anyone in New Jersey want 2 cheap M103 trailers?

    At this point I’ll give whoever takes the Gens to FedEx freight to me both trailers to do what they want with them
  3. B

    Anyone in New Jersey want 2 cheap M103 trailers?

    These do not have covers. They are generator trailers. I’d like to get these picked up this week if possible. I have attached a picture. There are 2 of them
  4. B

    Anyone in New Jersey want 2 cheap M103 trailers?

    I won 2 power distribution units (2 trailers with 4 MEP-803a’s), located in Verona, NJ. With fuel rates it’s not worth it to ship the gennys with the trailers but I can ship just the Gens thru FedEx with my corporate account. I need someone that can pick up the trailers, dismount the Gens and...
  5. B

    MEP-803A: It Runs, It Generates, but it won’t shut off

    I only removed 2 at a time just for this reason. Had that issue before and learned my lesson lol
  6. B

    MEP-803A: It Runs, It Generates, but it won’t shut off

    Some Progress! not entirely fixed but I did make some progress this evening before it got dark. I started with one of the suggestions above by adjusting the pumps. I rotated them all to where the pump inlet was as far towards the pushrod jugs as possible. I then started the machine and let it...
  7. B

    MEP-803A: It Runs, It Generates, but it won’t shut off

    I have not load tested the machine yet. I will double check the positioning on the lines this evening and report back
  8. B

    MEP-803A: It Runs, It Generates, but it won’t shut off

    I did read that thread prior to post my issue. The fuel solenoid, linkage, and rack appear to be working as they should. When starting the machine, the solenoid it actuating to open the fuel rack/pumps and when the S1 star switch is turned off, the solenoid returns the lever back closed butthr...
  9. B

    MEP-803A: It Runs, It Generates, but it won’t shut off

    So I bought this 803a as a non runner with 1000 hours on it. I had it delivered with about 25 other machines and it did not have the exhaust flap on it which subsequently got water down the exhaust and ending up in the crankcase mixing water with the oil. I drained all that out and added fresh...
  10. B

    MEP-804b Potentiometer/Voltage adjustment

    MEP-804b question: On the MEP-804b, is the potentiometer knob/assembly the same from an 804 to 805 and 806? I know it needs to match the VR whether is be a Libby or TRC but other than that, can I rob one off an 805 to use on an 804?
  11. B

    MEP-802a Power on only 1 leg?

    I’m not as well versed in the labeling of the parts but which one is the K1 relay? Is that also know as the circuit interrupter?
  12. B

    MEP-802a Power on only 1 leg?

    Got out there again today to mess with it. Nothing on the machine appears to have been tampered with. Cleaned all the electrical components with cleaner and worked the S8 switch a bunch and no change. Started it up and the gauge shows 120v when it should be at 240. What I found interesting...
  13. B

    MEP-802a Power on only 1 leg?

    Just picked it up so previous history is unknown. This is the first I’ve had it running. I’ll recheck both selector switches. I didn’t take the top off to check the contacts of the rear selector switch under the control panel so I’ll probably start there and check the circuit interrupter as well.
  14. B

    MEP-802a Power on only 1 leg?

    yes settings on the back panel and front panel are correct
  15. B

    MEP-802a Power on only 1 leg?

    I have an 802a with only 34 hours with an issue I’ve never seen. Searched the TM and didn’t find an answer either. Got the generator all serviced up and it purrs like a kitten. I have power on all lugs it’s supposed to on 3 phase but when I have it set for single phase 240v, I only have power on...
  16. B

    Anyone near Fayetteville, NC to pick up 2 Gens?

    I have an MEP-802A mounted on a trailer (pintle hitch) and a second MEP-802a skid mounted that I need to get picked up before they are considered abandoned. Covid put me in the hospital for nearly a month which really put me behind. Anyone near here?
  17. B

    MEP-803A won't start

    reading thru this thread it looks like the injectors themselves were clogged? I’m having pretty much the exact same issue. Bled system thru IP’s and have good flow/pressure at injectors but will not run. Smokes pretty good while I’m trying to crank it and “acts” slightly like it wants to start...
  18. B

    MEP-803A no start

    Ensure all lines were free of debris, new fuel water sep and inline element filter, then bled them to the injector pumps. Slightly loosened hard lines on the top of injector pumps and cranked machine until I had steady fuel flow and then tightened. Then cracked hard line at each injector on top...
  19. B

    MEP-803A no start

    The Airtex E1074 round body pump instead of the the square Faucet pump
  20. B

    75902lv Master Start Switch for MEP-80x Gens. Who has one for sale?

    just now seeing these posts but yes I was able to buy a couple from another gentleman and had one sent to Kurt direct