  1. gringeltaube

    24VDC Generator Update

    Sorry but I just don't see the problem here... :? Your dataplate clearly shows the NSN 6115-00-017-8236. That corresponds to the MEP-025A 28V DC generator. The correct TM is the one mentioned: TM 5-6115-323-14 (-14P), also TO 35C2-3-385-1. That manual covers both the 60Hz AC and the DC units. G.