    MEP-002A and -003A main breaker

    There are 3 fuel pumps. Two are hooked up in series to supply fuel to the injector pump. The third, or "Auxiliary Pump" is strictly to transfer fuel from an external tank to the on board tank so it can be run for an extended period. If one of the other pumps is running and working correctly...
  2. W

    MEP-002A and -003A main breaker

    I have "restored" and sold around 30 002a and 003a units and over a dozen 004a, 005a, 006a, 805a and 806a units. Load tested the 002a units at 8KW for an hour and the 003a units at 13KW for an hour. No breaker trips. The utility class MEP units are rated to start a 3-phase motor of a...