tarster's latest activity

  • T
    tarster reacted to FarmingSmallKubota's post in the thread First MEP-803a with Love Love.
    My My thats a pretty alternator
  • T
    tarster replied to the thread First MEP-803a.
    Thats what i was thinking, batteries are only a few months old, but... I have not had them on a trickle charger for the past few months...
  • T
    tarster replied to the thread First MEP-803a.
    Got the Genny back and running like a top! I first got the wrong size belt which was giving me some fits, went and found a seller on...
    • 20240528_105416.jpg
    • 20240528_105423.jpg
    • 20240528_105434.jpg
    • 20240528_105515.jpg
  • T
    tarster replied to the thread First MEP-803a.
    Appreciate the comment, I may get something that has a float or like some of the the other folks said using the double tap and just...
  • T
    tarster reacted to ctfjr's post in the thread First MEP-803a with Like Like.
    I know I'm late to the party on this interesting thread (also haven't posted on the forum in years) but I would like to throw a comment...
  • T
    tarster replied to the thread First MEP-803a.
    Highly possible, when disconnecting the wires I did see that the exciter stud was really loose, Im still going to put the new one in...
  • T
    tarster replied to the thread First MEP-803a.
    Finally had some time to get on this, turns out the alternator that was in there was a prestolite so I may just try putting a new...
    • 20240423_162803.jpg
    • 20240423_162809.jpg
    • 20240423_162814.jpg
    • 20240423_163002.jpg
    • 20240423_162921.jpg
    • 20240423_162933.jpg
  • T
    I ran #6 wire 115' run. Run single phase 120/240 . Only running Necessary equipment for storm condition, rated nameplate of generator...
  • T
    tarster reacted to Light in the Dark's post in the thread Can I revisit wet stacking? with Haha Haha.
    By the looks of it, I assume a CO tasked it solely with charging a battery powered toothbrush its entire 500 run hours.
  • T
    tarster reacted to Digger556's post in the thread Can I revisit wet stacking? with Love Love.
    Summerpaws - You mentioned typical outage is 1700-2000 watts for ~4hrs at a time, 4-5 times per year. If I were in your situation, I...
  • T
    tarster reacted to loosegravel's post in the thread Can I revisit wet stacking? with Like Like.
    I retired from the local transit company here 2 years ago. The first time that I saw "wet stacking" was at work. We have a crew of...
  • T
    tarster reacted to Guyfang's post in the thread Can I revisit wet stacking? with Haha Haha.
    Well, thats hard to say. But if I ran a gen set for a week or two at low loads, I would maybe think about hooking up a load bank or some...
  • T
    tarster reacted to m32825's post in the thread MEP-803a : AirTex fuel pump substitution with Like Like.
    My 803 had a Facet 40193 primary fuel pump installed in it. I was having problems with it dragging down and shutting off after brief...
  • T
    tarster replied to the thread First MEP-803a.
    Im planning to take it apart when I get it out of the gen set here and see what I can see and test before buying anything.. New ones are...
  • T
    tarster replied to the thread First MEP-803a.
    I went and looked that up, the number that is easily seen is the voltage regulator part which who knows may be bad.. Lol I think the...