  1. M

    803/802A Alternator

    I have a few of these machines for my shop, camp, and house I would like to have a few spare alternators around incase of failure. The NOS are very expensive and hard to find. Has anyone found a substitute for them? If so can you provide a part number or link? Also what is the most common...
  2. M

    Fuel Issues

    I have an 802A that runs my hunting camp, this weekend after running a heavy load on it to clean it out. The set shut down with a no fuel indicator. The gauge looked over full at first, then went to empty a few mins later. I opened the cap and the tank looked over full, the fuel level was up...
  3. M

    803a indoor operation

    Looking for some ideas, I want to store and run my 803a out of this shed. I have a couple questions. 1. I want to make a 90* turn straight out of the side with the exhaust. Then another 90* elbow facing downward. This should keep the rain out. I’m thinking up with an exhaust flap may be bad. I...
  4. M

    Fuel water separator

    Does anyone know the quality of the stock fuel water separator on an 803a verses a WIX fuel water separator? I can’t seem to find out any info as far as micron rating on the stock ones. I found a couple new in box ones for sale. Reason being is the drain valve setup is much cleaner on the stock...
  5. M

    Sync switch

    Might anybody know where I can find the small bulbs on this switch, I found the larger ones on line. I have no TM for it and can’t find the part number. Also if someone had a TM that would be great!
  6. M

    DIY load bank

    Need some help with using these 5kw dryer elements for a load bank. I understand I will need breakers, fan’s, housing etc. I’m not sure how these are wired, is it #1 = 120 and #2 = ground? I read another guys post on this topic. But the wiring specifics I still need. Thank you
  7. M

    24v alternator?

    Can this 40a alternator from prestolite be use as a replacement provided it has the same moi ting and terminals on it?
  8. M

    Steel drum AUX fuel adapter

    Can anyone tell me the ID of the copper tube that is associated with this adapter. I picked it up for pretty cheep and figured I would just add it later 🤷🏼‍♂️.
  9. M

    Mep 803a Voltage Adjustment

    So I ran my house on my gen set for the whole day since we are coming into hurricane season down here and I wanted to give it a good exercise. The machine worked flawlessly, I am back feeding into my panel through a 60a breaker with 4/4 SOOW cord and a pin and sleeve connector. So once I am...
  10. M

    Three phase / Single phase

    Does running an 804 wired for single phase damage the gen head at all?
  11. M

    Mep 803a heat venting

    So I am getting rid of this generac junk in the picture. An 8 x 8 foot slab is being put where this one is tomorrow. I will then build CBS block to make a room for the generator with a steel door on the front. The house wall is CBS as well. I am trying to get some ideas of how to vent the heat...
  12. M

    Mep 803a Percent rated current

    Thanks for all the help in my last thread but I have some more questions. The “percent rated current” gauge. Either was explained to me by the gentleman I bought the gen from that this is the gen output. He said you wanted to run the gen at 75% to avoid wet stacking. I must say I am impressed...
  13. M

    MEP 803A Overheating

    So I have navigated old threads to the best of my ability. I recently picked up an 803a with 500 hours. Last night I changed all filters and fluids, also replaced the temp gage that was broken. I fire it up and within a few short minutes (maybe 4/5 min) the temp was at 200 + degrees. It wasn’t...