  1. Bob H

    M880 5.2 smoke coming out of air breather inlet

    With the 727 trans the pump does not circulate fluid while in park. I will put mine in neutral for a minute before putting in gear. It helps the stall out. Also trans fluid level cannot be checked in park, must be in neutral.
  2. Bob H

    M880 5.2 smoke coming out of air breather inlet

    I put a clear inline filter just before the fuel pump. Yes where the fuel line connects to the carb.
  3. Bob H

    M880 5.2 smoke coming out of air breather inlet

    Change the fuel filter, I have found the rust particles from the metal fuel line can get in the seat and let fuel go by. when this has happened I would loosen the the fuel line at the fuel bowl & allow the back flow to rinse the seat. 2nd cause could be the starter relay on the fender well...