  1. Speddmon

    Need alittle help concerning Gensets

    Agreed! These are just normal diesels, not multifuels like the deuce. If you would run WMO/WVO through your pick-up truck diesel, then feel free to run it in the generator. But I wouldn't do it, for just the reasons that Carl mentioned
  2. Speddmon

    Need alittle help concerning Gensets

    That's what we're here for :wink:. There are some other sites with really good information about these generators, but the way I see it is this. S.S. is the premier site for information about military vehicles and equipment correct? Since these are pieces of military equipment, I want to have...
  3. Speddmon

    Need alittle help concerning Gensets

    Think about what you just said here, and look at what you posted earlier. What's the max rated current output of your set? 52 amps, you're feeding through a 60 amp breaker...it's not going to trip before overloading your set. Granted, these sets are heavier than you are going to find in the...
  4. Speddmon

    Need alittle help concerning Gensets

    It doesn't meet any code requirements at all, but a lot of people do it. It's dangerous for the linemen working on the high voltage wires where ever they may be if your service disconnect was not turned off. But I can tell you this much, if you ever do it this way and forget to turn off that...
  5. Speddmon

    Need alittle help concerning Gensets

    First off, congrats on getting it running. No, it will not hurt it to run on one fuel pump, just disconnect the power to the unused one so it doesn't run dry. You can buy another one from your local NAPA or o'reillys, they both can get the "Facet" pumps, just get them to look through the...
  6. Speddmon

    Need alittle help concerning Gensets

    Ike, you're not really disagreeing with me. The Lombardini engine is a commercial engine, yes it is newer, but it is still not rated for 24/7 operation. While the Onan engine on the MEP's was designed for military use, and they found a use for it on their civilian products as well. They are...
  7. Speddmon

    Need alittle help concerning Gensets

    Redundancy is exactly why they have so many fuel pumps. In the field, you can have a fuel pump fail, but the odds of both of them failing at the same time...pretty slim. It'll keep you going until you get to do some maintenance on it. The two main pumps are just that, they feed the IP with...
  8. Speddmon

    Need alittle help concerning Gensets

    Well, the oil leak sounds simple enough...one of mine was leaking around that valve as well, I just took the hose from it's storage connector on the upright angle and gave the valve another turn into the pan to tighten it up some. Yours sounds equally as simple. Your disconnected fuel line, on...
  9. Speddmon

    Need alittle help concerning Gensets

    From what you described, the fuel lines would be my only place for concern...other than the oil leak of course. Where is the leak located? What fuel lines are off and from where? Are they just off of the tank, are they off of the IP or the filters? As long as the steel lines on the IP are...
  10. Speddmon

    Need alittle help concerning Gensets

    very well put Carl, The main advantage to diesel sets, in my opinion, is the storage of diesel is a lot less sensitive than gas. Higher flash point, so it's more stable. Plus there is no carb to gum up if you don't properly maintain it. I always have at least 1 drum of off road diesel around...
  11. Speddmon

    Need alittle help concerning Gensets

    bevanet, first welcome to the site, no wet stacking does not affect only turbo diesels. It can actually affect your air cooled generator, but not as easily (since it's air cooled, it would get to a higher temperature easier, with a lighter load). Wet stacking occurs in any diesel when it does...
  12. Speddmon

    Need alittle help concerning Gensets

    it's all going to depend on your load requirements...if all you are going to run is a refrigerator, possibly a deep freezer and a bunch of lights, you can easily get by with a 3kw set. If you want to run window A/C units, you need to step it up some. Central A/C, need to look at the full load...
  13. Speddmon

    Need alittle help concerning Gensets

    USAFSS-ColdWarrior, I too was going to get the biggest honking generator I could afford until another member mentioned wet stacking quite a while ago. As an electrician I knew full well, that my actual requirements needed in the event of an outage were no where near even the 15KW for an...
  14. Speddmon

    Need alittle help concerning Gensets

    15 and 30 KW sets are awfully big for home back-up power...unless you have an awfully huge house. But the models are MEP-004a for the 15KW, MEP-005a for the 30KW. The condition codes on GL have an explanation with them. But unserviceable in the military's eyes isn't necessarily...