    KLChurch replied to a thread MEP-004A, No output in Generators
    update I assembled the float into the tank without checking to Guys test procedure. I took a gamble that it was OK. That was yesterday. Wanted...
    692 replies | 9326 view(s)
  • KLChurch's Avatar
    11-14-2019, 13:35
    KLChurch replied to a thread MEP-004A, No output in Generators
    This is the sealant I picked to seal the float. It says it is a rubberized sealant. The rubber gasket is not in good condition and I'm not electing...
    692 replies | 9326 view(s)
  • KLChurch's Avatar
    11-13-2019, 20:43
    KLChurch replied to a thread MEP-004A, No output in Generators
    The H1 in my pic will be finished with a four cyl Cummins before Xmas. Cant wait to drive it and paint it to so to thank you for your service. On...
    692 replies | 9326 view(s)
  • KLChurch's Avatar
    11-13-2019, 19:35
    KLChurch replied to a thread MEP-004A, No output in Generators
    So we will see if the float is the correct unit for the gen. While disassembling the float it had a rubber gasket plus some silicone gel. Maybe this...
    692 replies | 9326 view(s)
  • KLChurch's Avatar
    11-10-2019, 20:32
    KLChurch replied to a thread MEP-004A, No output in Generators
    Also I want to include an update of the starting of the gen. It fires up immediately every time I try to start it. I have not been disconnecting the...
    692 replies | 9326 view(s)
  • KLChurch's Avatar
    11-10-2019, 19:28
    KLChurch replied to a thread MEP-004A, No output in Generators
    Update, uninstalling the float was a back breaker and half of the screws you cant see. You have to use a stubby flat head screw driver because of...
    692 replies | 9326 view(s)
  • KLChurch's Avatar
    11-03-2019, 20:34
    KLChurch replied to a thread MEP-004A, No output in Generators
    Update Had to prepare for a family reunion. I was hosting. (someone gave me Cuban cigars, man they were smooth) Plus I actually had to work for...
    692 replies | 9326 view(s)
  • KLChurch's Avatar
    10-31-2019, 18:51
    KLChurch replied to a thread MEP-004A, No output in Generators
    The weather here is now is in the 50's and 60's . So I don't expect the gen to get hot. Will be connecting more units to get a higher load. Trick...
    692 replies | 9326 view(s)
  • KLChurch's Avatar
    10-30-2019, 18:01
    KLChurch replied to a thread MEP-004A, No output in Generators
    Discovered the oven is totally gas. I might be able to connect a hot water heater that I have. I can connect several 110 units to increase the...
    692 replies | 9326 view(s)
  • KLChurch's Avatar
    10-30-2019, 12:14
    KLChurch replied to a thread MEP-004A, No output in Generators
    Ok, I will make a 2 hour run. The dryer shuts off after an hour. So I will run the dryer twice. Then I will make another two hour run. The...
    692 replies | 9326 view(s)
  • KLChurch's Avatar
    10-28-2019, 23:09
    KLChurch replied to a thread MEP-004A, No output in Generators
    Started the gen and ran the dryer for over a hour. Had to adjust the hz twice and volts once. (not very much) After I shut down the dryer the hz...
    692 replies | 9326 view(s)
  • KLChurch's Avatar
    10-28-2019, 18:40
    KLChurch replied to a thread MEP-004A, No output in Generators
    Guy That's what I was thinking but I was told not to connect L0 to anything. Just connect the transformer ground to the frame and the frame to the...
    692 replies | 9326 view(s)
  • KLChurch's Avatar
    10-28-2019, 16:09
    KLChurch replied to a thread MEP-004A, No output in Generators
    This was finished today. Connected a breaker box to transformer. Connected a dryer to breaker box. Lastly one of my pet deer's. (you have to zoom...
    692 replies | 9326 view(s)
  • KLChurch's Avatar
    10-28-2019, 16:01
    KLChurch replied to a thread MEP-004A, No output in Generators
    This s the connection from gen to transformer
    692 replies | 9326 view(s)
  • KLChurch's Avatar
    10-21-2019, 19:01
    KLChurch replied to a thread MEP-004A, No output in Generators
    I have two test subjects. A dryer and oven. (maybe 60 amps total. Haven't checked the tags) Had to get my tractor running this weekend to move...
    692 replies | 9326 view(s)
No More Results
About KLChurch

Basic Information

About KLChurch
Biography:
Oil Field Threads of Tubular Products since 1974
Location:
Montgomery/TX
Interests:
No real hobbies
Occupation:
Manager of Engineering

Signature


Murphy is my friend

Statistics


Total Posts
Total Posts
474
Posts Per Day
0.21
Total Thanks
Total Thanks
212
General Information
Last Activity
Yesterday 19:25
Join Date
08-28-2013
Referrals
0
iTrader Profile Recent Ratings
Feedback Score:
Positive Feedback:
0
0%
Members who left positive:
Members who left negative:
0
0
Total positive feedback: 0
Submit Feedback For KLChurch
View Complete Feedbacks for KLChurch
  Past
Month
Past
6 Months
Past
12 Months
  0 0 0
  0 0 0
  0 0 0