  1. bmorrow

    going back to 24v

    I have an extra original one I'd be willing to sell. In great shape and works.
  2. bmorrow

    Post your cucv pics here

    I didn't myself. Bought it that way. It was an ex-police vehicle so some time in its history I think a sheriffs office did everything you see
  3. bmorrow

    Post your cucv pics here

    No sir. Bought it that way. It was an ex-police vehicle so some time in its history I think a sheriffs office replaced them.
  4. bmorrow

    Post your cucv pics here

    Here's mine.
  5. bmorrow

    going back to 24v

    I'm not sure bc mine started working once everything was hooked up right. I think there is a thread under FAQ about it.
  6. bmorrow

    going back to 24v

    I just wanted to thank everyone for all the help. I was a newbie to these Cucv's and now I've learned a lot and enjoy it so much. The problem was the glow plug relay. It was pulling 4 volts to the ignition wire. New gp relay and I have 14.5v to he front battery. I know have a somewhat factory...
  7. bmorrow

    going back to 24v

    Yes. They both turn off after start too. When I crank gen 1 goes off but gen 2 doesn't.
  8. bmorrow

    going back to 24v

    Right. Im going back to 24v
  9. bmorrow

    going back to 24v

    It is reading where one alternator is charging but why lol I have two alternators hooked up
  10. bmorrow

    going back to 24v

    Both relays are working.
  11. bmorrow

    going back to 24v

    This is what I'm getting.
  12. bmorrow

    going back to 24v

    key on (engine on) brown-12.25 red-12.05 key off- brown - 0 red-12.4 new heater fuse as well new exciter plug also brand new alternator but there is a chance its bad. with all this electrical stuff it may be fried also my volt meter never gets in the green. stays in the yellow
  13. bmorrow

    Generator test

    what was the conclusion? I'm having the same problem
  14. bmorrow

    going back to 24v

    So I made some major ground on the CUCV today. I got an idea that I should get the relays. I found the generator 2 relay was bad. It was kind of by chance. I just pulled it and put a new in and hooked the isolated ground wire to the hot block and it worked! no arcing. Just thought I would share...
  15. bmorrow

    going back to 24v

    I'll test it to verify its working correctly.