I tried unplugging the hour meter last night for the first time no effect....what is the rectifier again?
Is there a way to use an electrical test meter to determine whats tripping up the circuit? can a regular boiler guy possibly figure this out?
ill send you the k8 if you want to try it out.
I literally already did that,
I tried the second k8 relay last night and confirmed the same results
https://www.ebay.com/itm/NOS-EAS-Systems-Thermostatic-Switch-8720725-1-668Z-670-668Z-671-5930012945759/112503944796?ssPageName=STRK%3AMEBIDX%3AIT&_trksid=p2057872.m2749.l2649
i will be...
155MM i still cant get over how you purchased the same replacement relay and it worked for you and not me!
I'm sure everything is wired correctly. - i even reinstalled the original k8 and no tripping the breaker on heat mode.
I'm at a loss.
I meant that the circuit breaker that provides power to outlet keeps tripping. its on a 20 Amp breaker (which always had no issue running the heater prior to the "K8 Red light of death").
Last night i re-wired the original K8 and the result is it doesn't trip the circuit any more,
but still...
So here is my update. for my H82 to bad K8 Relplaced with one purchased on eBay.
I just messed around with the heater today,
I printed your wiring diagram and brought it with me.
I made sure the connectors were all on the right terminals with f1, f2 Etc.....and that none them were touching...
wait so it really worked for you???? That's awesome.
can you possible take another picture or two of the rest of the wire harness? just to see?
Thank you.
No the original issue was the K8 reset button no longer works and fuel pressure wont come up once switched to heat.
- this started happening right after my father told me he did a hot shut down with out running the fan.
....even though i stressed to him that is a big NO NO.
I'm really...
Soooooooo, i haven't messed with this heater since last year. But to give an update i found this a white Rodger thermo swich on ebay part number is 668z-671 - its got all the same color wires white black red and orange. All the same labeled terminals.
I had purchased it last year and when...
Revisiting this thread now that's it's cold again - I'm attempting to finally fix this h82 can someone tell me the difference between the following parts 668z-671 vs 668z-670?