So, new 1N5406 3 amp diode. Fired right up dragged it outside ran it a bit. Shut it down, no 24 volts. Well wiggled the connect p8-J6 connector'
Yup, 1 corroded pin set. cleaned up all good, thank you Kloppk.
One more question, upon start up the under current light will come on, I dont think...
Batteries charged
Dead crank-Yes
S17- pulled out 24.5 volts both sides
S1- off 24.5 volts pin 3
CB1- 24.5 volts both sides
CR1- 24.5 volts both sides
S1- master switch- any position but off, No 24 volts on any of the previous listed places
As previously stated it would crank and run with a...
Hello everyone, I have been searching for answers but not getting far. A friend has a 1993 MEP-805A with 21 hours on it. To begin with was it would sometimes/run start but when it it would not crank he showed me how he drops the control panel down and wiggles the wires in the area of S1 and S17...