Recent content by Gustavo

  1. G

    generator MEP802

    hi thanks for replying yes( is on the Normal position ) i know starter is good before i replace the alternator it was running for 2 hr and the engine stop i waited 5 to 10 min the engine work for another 2 or 3 hrs they recommend to change the alternator but now this problem , i appreciate...
  2. G

    generator MEP802

    hi bout a new alternator i connected the wires same like the old one her is my problem when i go to the side to the Dead Crank Switch flip the nob to the crank position a make the noise that engine want to star ( i charge the batteries Change the FU1 fuse Check CB1 is in the right position...
  3. G

    generator MEP802

  4. G

    generator MEP802

    hi yes i'm going to take to get rebuilt this way keep the original thank you four the that information
  5. G

    generator MEP802

    thank you for the information i' m going star searching those places i really appreciate .
  6. G

    generator MEP802

    thank you for your advice am take to rebuild also ( light dark ) send me a website for company they sell alternators hopefully i can fine the original thank you
  7. G

    generator MEP802

    hi thanks to expert that help sorry i took me a while to get to the right forum ; am new a the site ; any advice is welcome regarding the alternator for MEP 802 is fire season they cut the power got to be ready thanks
  8. G

    generator MEP802

    hi have a problem with alternator i can find the original anybody know a website .i bought alternator 24 bolts from my local auto part has 2 connections i install the one but a run for 5 min the engine turned off also when is running i disconnect the battery cable the engine turned off i...
  9. G

    MEP-802A Popping CB1 as Soon as the Unit is Switched to Pump/Prime

    hi I am locate in southern California (San Diego ) Thanks for the help on the generator problem I hope i can help somebody out there just like you help me by
  10. G

    MEP-802A Popping CB1 as Soon as the Unit is Switched to Pump/Prime

    thank you very much for you advice i noticed to that needle on the battery charge is not on the green line once in while i had to charge the battery i am going to test the alternator or replace appreciate your help thank you
  11. G

    MEP-802A Popping CB1 as Soon as the Unit is Switched to Pump/Prime

    hi i am new at this channel I purchased a MEP 802 generator a year ago with 130 HRS No problems until now i run this generator every other week for at least 30 min they shut power and that' when i noticed the problem , run for 2 hr a 20% and stop working i try restarted but struggle is...