• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

Recent content by Kiki

  1. K

    LMTV Air Conditioner

    R134A but i think that i will try something else as i checked the temp at the evap inlet and it was only 60 F so i will evac and maybe loo into the expansion valve as i think it should have been closer to 40 f at the evap inlet. thats good to know that this was originally an R12 based system.
  2. K

    LMTV Air Conditioner

    i am using harness RD-4-6001-0 and just making connections as i will need to ( I am using Wiring Schematic R-5750) and then sourcing a 2 wire Binary Switch (RD-5-4640-0P) that opens at 30 and then again at 300 which should provide protection needed for the AC system. as for the switch on the...
  3. K

    LMTV Air Conditioner

    Thanks, i am about 95% complete with the install of the AC, just waiting on a red dot binary switch and making 2 brackets for the condenser. looking at the pressures i have a good differential between high and low but the temp at the outlet is only 50-60 degrees F with the outside temp of 80-85...
  4. K

    LMTV Air Conditioner

    What amount of refrigerant is used in the system? i just serviced mine with 3.5lbs of R134 and it seems like it was more than it needed.
Top