• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

Recent content by KnuckleDuster

  1. K

    Mep-802A crank no start, high crankcase pressure

    Engine runs like a top now! A little smokey but I haven't ran it long enough to seat the rings. My oil pressure gauge is bad so I ordered a new one and don't want to run it long until that's replaced. Other than that it does make power and function how it should!
  2. K

    Mep802a won't shut off!

    Any brands you recommend? Sender/ gauge combo?
  3. K

    Mep802a won't shut off!

    You nailed it! 137T was hooked up to the lug (regulator) not excite. I swapped em over and it works perfect now! Can't thank you guys enough for all the help!
  4. K

    Mep802a won't shut off!

    Ray can you help me out with the alternator wiring? I've got no wires on the stud labeled "excite" or "ac tap"
  5. K

    Mep802a won't shut off!

    I'll give that a shot soon and let you know what happens. This is certainly an interesting situation.
  6. K

    Mep802a won't shut off!

    But something I find strange is that if the engine is off and I just cycle through s1 functions everything works normally. And If I just bump the start but don't allow the engine to actually start, when I switch s1 back to off the solenoid closes and the panel turns off. It's only when it's...
  7. K

    Mep802a won't shut off!

    Yes that is correct
  8. K

    Mep802a won't shut off!

    Just checked it, and yes it appears everything stays on and keeps working normally
  9. K

    Mep802a won't shut off!

    Photo posted
  10. K

    Mep802a won't shut off!

    Alright, tested all the wires, they all check out okay. Signal removed from gauge ohms at 240. 23 volts at the gauge and ground is perfect. Attached photos are the gauge with key off, as soon as I switch it to run position, and the photo of the start switch. It is indeed there. So I'm thinking...
  11. K

    Mep802a won't shut off!

    Hey fellas, recently purchased a 2009 mep802a off gov deals and got to working on it. Ended up having to rebuild the engine, got that done and it fired up beautifully. Makes power but I've got two issues. Oil pressure gauge is pegged at 80 and stays there even when off. I know it's not making...
  12. K

    Mep-802A crank no start, high crankcase pressure

    Everything in the engine is still standard size! I have no reason to believe this engine was ever opened up in the 3400 hrs it's logged so far. Just really hoping after all this it makes power
  13. K

    Mep-802A crank no start, high crankcase pressure

    I've had the head torn down and soaking in my parts washer. My rebuild kit came with new valves, tomorrow I'm going to lap them in and pre-assembled the head. Then I will test for leaks. Today I got the new pistons and rings installed, new rod bearings, pushrod housings and seals replaced. I'm...
  14. K

    Mep-802A crank no start, high crankcase pressure

    Thanks for the heads up. Most of the parts I ordered I'd rather not use used parts but if I need anything else I certainly will!
  15. K

    Mep-802A crank no start, high crankcase pressure

    Another little update plus more bad news, got the pickup and relief valve removed. I'm unsure if the relief valve plunger is supposed to move or not but when I went to pull it apart the plunger was completely seized and it was very rusty internally. Heated it up and got the plunger out, it was...
Top