Well I seem to be on the right track just still wrong part #, I thought I found one at 375f -400f but the one I have is only L320f which is still below listed operating temps. if anyone with a working SHC-60 would be kind enough to let me know the part number on theirs it would be greatly...
From what I have been able to figure out although they are similar they are different and don’t plug in directly due to different size spade connectors, so decided to do some research first.
the 35 has a max listed temp at the grill of 240f and the thermo limit switch installed in both of them...
Hello all,
I picked up a couple SHC35 and got them running great , I also picked up a SHC60 that keeps tripping the manual thermostat reset switch . I followed the TM and tested the switch which tested fine , there are no obstructions in the unit and no other faults , what are the odds it’s...
Hey guys I’m doing a 4 man soft top and using the c pillar from fed mil parts , if anyone has used the same one with a soft top I would like to ask you a question
Thanks
Sent from my iPhone using Tapatalk
Well,
she’s back up and running like a champ , I couldn’t have done it without all of your help and suggestions thank you to everyone and especially Kurt who patiently took time to send me some detailed help anyone needs anything, please let me know
Sent from my iPhone using Tapatalk
I really appreciate all the help guys , I haven’t found anything yet other than a nest I cleared out. Going to call it a day and head home, she will sit until I get up here again prepared to tear in and have look, any other ideas let me know , thanks again
Sent from my iPhone using Tapatalk
So guys guys are correct something made a nest in there but I’m now seeing anything chewed up everything looks intact
Sent from my iPhone using Tapatalk
I’m checking but I don’t see anything and now if I connect the batteries it just cranks no matter what position the dead crank switch is in
Sent from my iPhone using Tapatalk
Hey Guys,
kind of in a bind i have an 802a up on some remote property that was running great last time I was up here about a month ago and last time I went to start it the starter just clicked as if it died and when I went to try it again I noticed K16 smoked , I went home bought a new starter...