  1. V

    Advantage or Disavantage of re-wired 400hz generator to 60hz?

    Higher frequencies can use physically smaller and cheaper transformers; so 60 Hz would be preferred over 50. Lower frequencies are less affected by skin effect; so 50 Hz is best here. Skin effect is where the AC current flows only on the outside portion of larger diameter wires, in effect...