MEP-802

Ray70

Well-known member
2,377
5,093
113
Location
West greenwich/RI
I assume you E-stop switch is pulled out and the CB-1 circuit breaker is pushed in?
If you have nothing at all, no panel lights nothing, check the shunt mounted near the right side, bottom inside the control box.
Also check the CR1 diode, I think it's 2nd up from the bottom on the panel to the rear left back wall of the control cube, below the 4 burden resistors, R10 - R R-13.
If either is open you will have nothing for DC power at the control panel.
 

birddog1106

New member
11
4
3
Location
southport,nc
I assume you E-stop switch is pulled out and the CB-1 circuit breaker is pushed in?
If you have nothing at all, no panel lights nothing, check the shunt mounted near the right side, bottom inside the control box.
Also check the CR1 diode, I think it's 2nd up from the bottom on the panel to the rear left back wall of the control cube, below the 4 burden resistors, R10 - R R-13.
If either is open you will have nothing for DC power at the control panel.
I got the power back with a LARGE HAMMER !! low fuel switch Hanging-up Installed new fuel pump 3181 I think was the number.Tks for your response VG
 

Ray70

Well-known member
2,377
5,093
113
Location
West greenwich/RI
Ok, so that would mean that you had 24V DC at the panel, you just couldn't start it because the low fuel fault should have been illuminated.
Were you getting a fault light when trying to start it?
Also, in a low fuel scenario typically the machine would start briefly then shut down within a few seconds with the fault indicator on.
Also a bad fuel pump would not cause "no power either", so I assume you had power, it just wouldn't start??
 

birddog1106

New member
11
4
3
Location
southport,nc
Ok, so that would mean that you had 24V DC at the panel, you just couldn't start it because the low fuel fault should have been illuminated.
Were you getting a fault light when trying to start it?
Also, in a low fuel scenario typically the machine would start briefly then shut down within a few seconds with the fault indicator on.
Also a bad fuel pump would not cause "no power either", so I assume you had power, it just wouldn't start??
AS Before,I had NO Power at on/off (red) button. dash lights did not come on untill that 5 lb did it`s job. Also the fuel pump E-8131 works great and easy installation. No fault light.............vg
 

Ray70

Well-known member
2,377
5,093
113
Location
West greenwich/RI
In that case you hammer action had to have done something else to "fix" a bad connection somewhere.
The fuel level sensor has absolutely no ability to disconnect 24V power from the control panel, so I think you just got lucky, but perhaps only temporary.
 