  1. Triple Jim

    output voltage crowbar

    When I did my measurement of regulator current while idling the engine on my 003A recently, I disconnected the regulator output briefly with the generator at 1800 RPM, and the output voltage was right around 160 on each 120 leg. When the regulator is disconnected, the transformer that supplies...
  2. Triple Jim

    output voltage crowbar

    3dAngus' point is a good one. I was assuming that loads sensitive to spikes spikes and brief overvoltages were already protected. Shutting off the generator engine in my case would be to protect things like refrigerator motors and lighting, and possibly the generator itself.
  3. Triple Jim

    output voltage crowbar

    Very interesting idea, Jason. You could wire a relay in the line with the oil pressure switch and simply stop the engine if a voltage out of range occurs. As far as expensive electronics go, I try to have all of mine on UPSs. They sense both over and under voltage and come on for either...
  4. Triple Jim

    How have you civilized your MEP Generators?

    Gotcha, makes sense now. It's on my list to put a strain relief on the side of my distribution box to get rid of the usual four wires dangling out the door.
  5. Triple Jim

    How have you civilized your MEP Generators?

    Looks good so far. I'm sure you have a good reason, but why are you bringing the wires in the top instead of keeping everything going in and out of the bottom so it's hidden?
  6. Triple Jim

    sooo.... anyone ever hear of...

    I think I'd smile and nod and back slowly away from that guy.
  7. Triple Jim

    MEP-002 idling

    Take a look at some recent testing I did with my MEP-003A. Specifically, I measured the output current of the voltage regulator with the generator's main breaker off, at different engine speeds. Since in this system the regulator reduces its output when it wants to increase AC output, it is...
  8. Triple Jim

    Mep003

    Best of luck with your surgery. I'm sure I'm not the only one pulling for a successful operation and full recovery for you. OK, now I get what you mean about the generator, thanks. I'll put some thought into that. It almost sounds like there's a shorted output, but as I said, with the 400...
  9. Triple Jim

    Mep003

    Just click the little icon of a picture, 2nd from the right in the quick reply box. Then click "select files". Then you can choose the photo from your computer and upload it. When you say "will go to full load", exactly what do you mean? Why are you really sad today?
  10. Triple Jim

    Mep003

    Sorry, I was thinking of the control cabinet. It looks like the differences are mainly the reactor and the current transformer. I would not expect things to work correctly with the wrong ones in the circuit.
  11. Triple Jim

    Mep003

    I'm trying to understand your last post, but (sorry) I'm confused by "I placed a 400 hrtz on mt acquired set from Maryland, started genset up, went right to max hrtz on dial" and "Took my other dist box on my personal 10 kw put it on other set ran fine". LuckyDog's post is on the money. By...
  12. Triple Jim

    mep-003a teardown and refurb

    No problem with the vertical scratches you can't feel. Perfectly normal wear.
  13. Triple Jim

    Noise suppression filters

    If you're a ham and operate in the HF bands, the filters might come in handy.
  14. Triple Jim

    How have you civilized your MEP Generators?

    Thanks Jerry. Jim, the printer is really neat. There are different types. This is an $800 MakerGear Prusa Mendel kit. It extrudes plastic from a nozzle and the X,Y, and Z motors drive it around to build up the part. The laser imaging type that harden liquid resin do much higher resolution...
  15. Triple Jim

    How have you civilized your MEP Generators?

    My MEP-003A's hour meter quit. Rather than buy a replacement 2-7/8" round type, I got a more commonly available and cheaper rectangular one from eBay for $14.95 delivered. Then I drew an adapter and my son used his new 3-D printer to make it for me.
  16. Triple Jim

    M1031 genset, how much power is needed to run

    I agree that the D722-E is a three cylinder engine. Also in the specs I found, it's rated around 18 hp at 3600 rpm. If the generator you have needs to be turned at 1800, that engine won't even come close to handling the job unless you use something like belts and pulleys so the engine can run...
  17. Triple Jim

    M1031 genset, how much power is needed to run

    With 100% efficiency, you'd need 16.02 hp. Assume you'd need at least 20. A bit more is good.
  18. Triple Jim

    Wil it matter if return is going through dip tube into bottom of tank

    I don't think the resistance of the tube will matter. It might matter if the incoming warm fuel gets sucked up and back to the injector pump immediately, but the two tubes would have to be pretty close together to get much of that happening.
  19. Triple Jim

    Tachometer for 002-003

    You can get an idea of what they are from the Tiny Tach web site: http://tinytach.com/diesel.php
  20. Triple Jim

    Tachometer for 002-003

    I've heard good things about Tiny Tachs. A lot of guys get a Kill A Watt meter for about $25 and plug it into the convenience outlet. It has a digital frequency display. I've used the little Chinese DC-DC converters that have cast finned housings in the past, and they don't last very long...