  1. C

    No power to the main fuel pump on MEP803a

    Hey, everyone. I recently purchased an MEP 803a with 320 hours. it’s in great shape and nothing seems out of place. However I’m not getting power to the main fuel pump through the master switch. Everything else works including the AUX pump. I can run a hot wire to the main pump and run the...
  2. C

    Mep 802A with some aftermarket messes

    Has anyone ever felt with a generator with one of these toggle switch panels before? I recently bought three from an auction all with these panels. All of them having a short and not producing power. I believe number 3 and 8 control the fuel pump but can’t locate any other functions with the...
  3. C

    Mep 803a not powering past 25%

    I have an MEP 803a I recently bout with 500 hours. I am running a camper that has two A/C units on it and it’s only running half of the camper. The output needle will not exceed 25%. My multimeter shows 240v and the receptacle is showing 140v but for whatever reason it’s not increasing the...
  4. C

    Low voltage on MEP 803a

    Hello all. New to this group with some experience with military generators. I recently purchased an MEP 803a from gov planet. 2007 with tier 2 reset done in 2011 with 220 hours. The unit is only producing 50-60 volts on the L1 & L3 lugs. If I flash the field it produces the normal 220v 60 hz As...