• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

Search results

  1. J

    Fuel drain for MEP 803A

    Looking for an original fuel petcock drain assembly. I took the OEM one out that wasn't leaking and put in the "upgraded" version and it leaks. Any help would be greatly appreciated. Thanks, Jason
  2. J

    MEP 803 A tripping CB1

    So after all the work I have done to this generator and I have it all buttoned up and ready for use the CB3 keeps tripping. It never did this before through the entire process. It's not a big deal because I reset it and it works fine I just want to know why. Any help is greatly appreciated...
  3. J

    MEP 803 A M8 % load gauge not working

    So first off thanks for all the help on my genset. My last post started as something else then wandered off when I found my M8 % load gauge isn't working. Several on here had some great suggestions for troubleshooting and provided some good diagrams. I'm currently looking for a good diagram of...
  4. J

    Test running the 803 in the house.

    Got the 803 hooked up to the house for the last hour and have a few questions. First off my percentage load meter isn't working so I'll have to figure that out. I've trimmed my voltage and hertz. When I check amps across L1 and L3 I get 42amp on one leg and 36-38 on the other. Is this normal...
  5. J

    MEP 803 A wiring help.

    I appreciate all y'all's help so far. I have my set up and running and I'm ready to hook it to the house. I just need to know what position my single phase selector should be and also how the wireing going out to my house should look like coming off the generator lugs. Thanks, Jason
  6. J

    Load testing MEP 803 A help

    I'll be doing a load test soon before hooking up to my house. The question is which way is better or does it matter? Run one wire on a 120v leg out to 4 outlets and another wire on the other 120v leg to 4 outlets and use heaters and such or to hook up on the 220v and test it that way or does it...
  7. J

    MOV mod Fuse mod 803 A

    So I seen the video from Callmecolt and just wanted to confirm this is a needed mod for the MEP-803 A. Thanks, Jason
  8. J

    MEP-803A genset no crank

    i just aquired a MEP803A with 45 hours on it. Bought 2 new batteries and get no crank from either locations. No prime also. The green lights come on with no prime pump and no crank. Jumped the solenoid and it spins. I also get no test lights except for battle and circuit open or closed lights...
Top