I removed, inspected and used a vault meter to test the relay and its plug ....... I think I fallowed some instructions I found on another post.
Any tips or tricks on testing the relays would be much appreciated
I’m back ... removed, inspected MPU ( no damage)
Reinstalled MPU and adjusted to now 2.3vac direct
Turn s1, set will crank for split second and stop. overspeed fault indicator illuminated .
I found the power potential transformer but haven’t tested yet ... I bet that’s the under voltage...
Update something different is happening now after unplugging the fault indicator
When I try start the set with battle short on it no longer cranks but under voltage and low oil shutdown fault lights go on
................umm maybe I’ve lost my marbles on this one but I thought the battle short...
I discontented plug on fault indicators ( box with fault light )
I turn s1, set cranks for split second then stops
Reconnected plug
Tried to start set again same thing overspeed lights up set cranks for one second stops
Tried to start with battleshort switch on, set will crank for a...
I turn s1 and hold 10 sec, generator will crank for split second then the engine stop overspeed light goes on, generator stops and will not crank .... also fallowed flap instructions and TM 9-6115-643-10 troubleshooting section
I am trying to get a Mep804a running with 108 hours, when I first got the generator it would crank but not start, I discovered the MPU missing and replaced it (nsn 6695-01-367-9723,88-21061) and adjusted to 2.88acv at A5 ( woodward gov control )
Now generator will crank for a second then The...