  1. J

    802a help

    Seems to work. I’ll check on it in the morning and see if it’s still working or not. On another note where would a guy pickup a emergency stop switch, a knob for the voltage select switch and either a coolant gauge or sensor. I can’t find the sensor to test it.
  2. J

    802a help

    So all three r10 - r 12 were either only connected by one strand had a solder joint broke or were broke off. Soldered everything and headed out to try it now.
  3. J

    802a help

    Just want to say thanks for all the help so far. You guys are a stand up bunch. I’m gonna solder that wire tonight as well as add my 100 gallon aux tank. I’m away for work 8 days at a time so I need it to run and not have to have some one fuel it while I’m away.
  4. J

    802a help

  5. J

    802a help

    R10 is .9 R11 is 2 R12 is 7.2 A wire has come off the solder joint. On the left side of r12.
  6. J

    802a help

    No it does not big down. It was 12 degrees this morning and the genset fired right up. I waited ten min and hit the ac close circuit. As soon as I hit the toggle switch it went into short circuit fault. I have a gas 5000w generator running the motors now and it is doing fine. So Im pretty sure...
  7. J

    802a help

    I would take one. How do I pay for it?
  8. J

    802a help

    I just went and started it. As soon as you apply a load it short circuit faults now.
  9. J

    802a help

    It reminds me of a coil for a spark plug. Works fine cold but warms up and fails. I’m headed back to the set this morning with daylight this time and try to investigate further. I’ll take pics this time.
  10. J

    802a help

    No
  11. J

    802a help

    500 ft. I have 2 hot conductors 2 neutral and one ground.
  12. J

    802a help

    I thought maybe my 5 conductor 6 awg cable I ran maybe got nicked but that wouldn’t explain why it worked for 30 min then shut off. It’s almost like it works when cold then as it warms up it’s starts failing.
  13. J

    802a help

    So I have 2.36 volts across R10 r11 r12. With about 30% load on the load gauge. And 0 volts across all three with no load. I switched the generator over to 120 single phase grounded the generator. The generator and everything worked fine for about 30 min then the short circuit light came on. I...
  14. J

    802a help

    I’m not sure that all my loads are on the same leg. As I’m using an outlet to power the motors. I have two outlets. And last time they were plugged in was by my nephew. If I’m pulling all of the same leg I’ll change it to pull off both. I think I might try running on 110v and not splitting 240...
  15. J

    802a help

    Single phase 120 motors. L1 and l3 are hot and lo is neutral I bieleve. I’d have to check on the grounding bar. I’m running it as i bought it. It worked flawlessly until I hooked 4 1hp motors to it. I started them individually and waited for them to ramp up before starting the next one. When...
  16. J

    802a help

    I just bought one of these to power two ice eaters for waterfowl hunting. Everything worked fine for awhile and now it started throwing an over load fault while running 3 motors So I unplugged one motor and now it throws a short circuit fault after about an hr of run time. Here is how it’s...