• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

 

Search results

  1. T

    MEP805B wont start

    could you private message mac and ask if he found one i know he said to have you message him if i needed it?
  2. T

    MEP805B wont start

    @mciikurzroot do you have a back plane i could have please and @Guyfang thank you so much for helping with this
  3. T

    MEP805B wont start

    yea i understand your pain with all of this stuff and hate how the trouble shooting always ends with " contact higher maintenance personnel" but could you contact mac and ask if he has a back plane that i could have please
  4. T

    MEP805B wont start

    ok I just checked voltage going into the back plane and have 24 volts on the side(p5/6) going into the board but only have 24 volts in some spots on the opposite(leading to p24/p9) side but not all, do you have a guide for troubleshooting the back plane?
  5. T

    MEP805B wont start

    ok I will but first id like to try some different things to verify first so I'm not getting 24volts at all my connections on p25 on the I/O module and the ones that look like they feed over to P9 and P24 which I think is causing me to not get 24volts to my electric actuator. do you know how...
  6. T

    MEP805B wont start

    ok I'm gonna run through those steps today with the procedures you sent me and if mac has a board he is willing to spare I would greatly appreciate it. also do you have a schematic for the pins that connect the DCS module to the back plane so i can try and measure voltages and continuity for...
  7. T

    MEP805B wont start

    ok I will try these steps tomorrow and I got it from someone off eBay that said it was working in December of last year. the next thing I was look at potentially replacing is the back plane since I checked the wires leaving the back plane to be good and the wires going into the back plane show...
  8. T

    MEP805B wont start

    just tried it and im still only getting 4 volts to actuator
  9. T

    MEP805B wont start

    the engine only cranks and only starts running when i shoot ether into it but once the ether runs out in the system it turns off ok ill turn mine into 3VAC
  10. T

    MEP805B wont start

    yes I tested it iaw the TM, received the new one and installed iaw the TM showing 1.5 VAC and im currently making sure the lines leaving the back plane to the mpu and electric actuator are good. I have been testing and verifying all relays and resistors on the inside of the DCS box.
  11. T

    MEP805B wont start

    I have a mep805b that was running six months ago and blew a fan belt, since than it hasn’t worked. It cranks but doesn’t turn over completely. When I use ether, it turns over and runs off the ether but dies once the ether stops feeding it. My MPU is reading 0 volts and 2.25k ohms (currently...