  1. F

    M200A Mobility question

    If you air up the service line last, I believe the air brakes will stay in the off position on the trailer when you disxonnect it from the deuce. Whether the brakes lock when you disconnect depends on which line you disconnect first, at least on my trailer.
  2. F

    rewiring MEP004 for single phase

    Hey This was my thread initilly. I have scoured the internet for any informtion about this conversion. It doesn't exist. So if you can post or send instructions and pictures I will get them posetd here. Great post, thanks
  3. F

    rewiring MEP004 for single phase

    Similar. The MEP 004 will be a touch better.
  4. F

    rewiring MEP004 for single phase

    I plan to. I have some ideas on some stuff I can run off of the extra leg. And I can probably use that 5 kw somewhere. Whatever I do, this will be a step up. Right now, my backup generator is the auxiliary coil on a Miller stick welder. Runs a couple of lights, and keeps the heat on...
  5. F

    rewiring MEP004 for single phase

    We'll see I really don't think that if you have a decent size property you can operate the Genny right, you should be able to load it up enough to blow the crap out the stack. Run your Stove, electric water heaters, AC, clothes dryer, Well pump, and 110 stuff like the Dish washer. I checked...
  6. F

    rewiring MEP004 for single phase

    Brian It looks like I will not get more than 10K out of this big genset after I rewire it. At least as far as Ike's post is concerned. I understand the military board would have to go. Attached ( if I did this right) is the wiring diagram and schematic for what I think would be the...
  7. F

    rewiring MEP004 for single phase

    I appreciate your reply regarding wet stacking. I believe that it exists. And is a problem I will have to deal with. You are right, Unless I am cooking, waching and drying clothes, running a dishwasher, or filtering the pool, my amp draw is minimal. Guess I will just have to live it up when...
  8. F

    rewiring MEP004 for single phase

    I have been lurking around looking for someone who has rewired an mep004 genset for single phase. I know that I can effectively use it as a single phase generator by pulling power from two of the three legs. What I am exploring is trying to avoid un-balancing the load on the third leg and...