    MEP-003A Load test

    Thanks for the offer Anthill, my concoction actually worked pretty darn good and it took only a few hours to assemble and about $100 in materials. I sold the genset last week so I'm all set. I do appreciate your offer though, everyone on this site is very helpful and accommodating; I can't say...
  2. R

    MEP-003A Load test

    Lol, you're a braver soul than me; I would never try that. Electricity scares the crap out of me, mainly because I don't know that much about it.
  3. R

    MEP-003A Load test

    Did you notice a difference? Less smoke emission? Do you add the ATF once or for a couple tanks? I've used the Marvel Mystery oil for other stuff but never as a fuel additive, thanks for the advice, I'll pass this on to the buyer. I did tell him about Steel Soldiers so I'm sure he'll be...
  4. R

    MEP-003A Load test

    Yes, counter sunk 1/4 inch screws, nuts and washers and globed them up with elephant snot, AKA silicon bathroom sealer. No backer plates just the screws and nuts; I let the silicon dry for 24 hours to make sure it was dry and used liquid pipe sealer on the heater elements to stop the threads...
  5. R

    MEP-003A Load test

    You can get them at Lowes or Home Depot; here's the Lowes link for the 1 inch floor flange. Get a good 1 1/4 metal hole saw to cut the holes in the drum; I burnt up two hole saws getting through the drum but the drum was thicker than normal...
  6. R

    MEP-003A Load test

    I'm selling it to upgrade to a Kubota GL11000 which are mighty expensive but much quieter and smaller. I got $4k out of it but I added some stuff to it such as an oil pan heater, new marine batteries and I have a bunch of new filters that go along with the unit along with the trailer which is...
  7. R

    MEP-003A Load test

    It smoked some but I've only run this thing with slight loads such as hand drills and an 110 volt welder for a few minutes so the exhaust is probably chalked full of oil from running this thing for 26 hours with little or no load. I bought it with 3 hours on the clock since the reset from...
  8. R

    MEP-003A Load test

    Ok, load test completed; 13,500 watt with 100% load and it ran like a champ. My make shift water boiler worked wonderful, thanks guys for all your input. Could not have done it without ya. Here's a video. https://www.youtube.com/watch?v=6SL23eFODgQ&feature=em-upload_owner
  9. R

    MEP-003A Load test

    Nice work Lee; my welds would never look that good hence the silicon and flanges. My welds always come out looking like chewed bubble gum with more holes than swiss cheese. I'll snapped a few pics of my make shift rig before the melt down on Sunday. Should be interesting.
  10. R

    MEP-003A Load test

    Thanks guys, So far I'm going to use a 3 separate wire set up with three elements rated at 240v 4500 watts. One thing that I came up with that I think will work with mounting these elements into or onto the side of the 55 gallon steel drum is a 1 inch pipe thread flange that I can mount with...
  11. R

    MEP-003A Load test

    Great points Ratch; I've been thinking about this and adding an additional element would make it that more of a proper test. I'm assuming that the ground lug on the set L0 will not be used and I'll just run the L1 and L3 lugs to each post on the 3 heater elements each with their own #12 romex...
  12. R

    MEP-003A Load test

    Ok, thank you just want to make sure. I appreciate everyone's help!!! You guys are wonderful.
  13. R

    MEP-003A Load test

    When you say box are you talking about the L1, L2, L3 and L0 box correct or the Square D box with the breaker? Just want to make sure I don't destroy anything in the process.
  14. R

    MEP-003A Load test

    Ok, I've lost ya here; the bonded jumper is on the skid frame of the generator correct? Mine is connected and it also has a copper lead that runs from that bonded jumper to a flat part of the trailer with a butterfly nut. I was thinking the bonded jumper stays connected and I run a copper wire...
  15. R

    MEP-003A Load test

    Ok cool, so the 100a picture is the Square D box. I'll snap some photos once I get everything set up; do you think a Copper rod spike for ground is needed or can you use a solid steel ground spike?
  16. R

    MEP-003A Load test

    Ok so I have 4 AWG wire I can run from the Genset to a square D breaker box with a 50 amp breaker and then to some 12 AWG romex. I should only need two heater elements since they should put a 9K load on the set which I think will be fine to test the unit out for 30 minutes or so. Since I'm...
  17. R

    MEP-003A Load test

    Well, had a change of plans on the spider box; can't find a reasonable price on something that is 50 amp that has enough regular 110v outlets for hairdryers. So Ratch I'm interested in your method of load testing; I found a drum and can buy a couple of 4500 watt 240 volt heater elements at Home...
  18. R

    MEP-003A Load test

    Awesome, this is a great idea; I could use a spider box anyhow so I'll look for one on fleaBay and go this route; you guys rock, great info thank you.
  19. R

    MEP-003A Load test

    Thanks Lee; thanks again but I think I may buy a spider box and run some hair dryers off it and load the genset that way since I'm pretty paranoid of electric shock; got zapped by a tow truck alternator once years ago and that was enough for me. :-D
  20. R

    MEP-003A Load test

    Thanks Lee for your response. I think I may have the unit sold so the buyer wants me to load test it before he commits which I understand but I was looking for an easy way to exercise the unit without too much trouble. I did search the auxiliary form and found a couple posts but nothing that I...