Search results

  1. E

    MEP 806B Low Frequency

    Thanks for the great info. This is exactly the response I was looking for. It has been busy here, so here is what I have been able to check so far. Data Plate indicates 806B 60hz Injection pump in the proper orientation All modules are secure Dip Switches on I/O and SW1 are in proper...
  2. E

    MEP 806B Low Frequency

    New to me 806B. 199hrs on clock. Added fluids, starts and runs well. Configured board and switch for 120/208v operation and frequency selector switch is in the 60hz/400hz position. CIM displays 54hz upon startup, frequency adjust toggle has no impact on output - up or down. Verified CIM...
  3. E

    Pettibone Crane TM's

    Thanks for the replies. Have the crane here at work. It was gone over a few years ago, but now seems to be exhibiting some mechanical deficiencies. I would like to troubleshoot in my spare time....it is a nice crane. Based on my knowledge of military TM's (limited to gensets), I know they can be...
  4. E

    Pettibone Crane TM's

    I'm hoping someone can point me in the right direction. I'm looking for the TM's for an old Pettibone RT Crane. Model#15B1WF FSN#3810.00.377.1464 Contract#DSA700.74.C846 Reg#12-31012 Any help would be much appreciated. Thanks
  5. E

    Gov Liq Generator Working Ratio

    I won two MEP-003's from Ft Meade and 1 nice MEP-004ask from Chambersburg. Both 003's had less than 5hrs on the clock, very clean fuel tanks, were missing oil filters, missing batteries, no oil. Converted Oil Filters to Spin On (Thanks Speddmon), Converted Fuel Filters to Spin On (Local...
  6. E

    Load Testing Gensets

    I completely understand the idea of wetstacking. I also understand how load testing works and the reasons it is done. As I stated in previous posts, I have no problem figuring out how to come up with a bunch of dummy loads if I wanted to accomplish a load test or an excercise. What I'm...
  7. E

    Load Testing Gensets

    I get all the different ways you can come up with some dummy loads to test the generator, especially the 003's. I too have an 004 and with oil heat in the house and an indirect water heater, short of running my welder at full tilt just to creat a load, I'll be in the same boat as...
  8. E

    Load Testing Gensets

    I recently purchased several nice sets from GL, two 003a's and one nice 004a. I have been reading the posts in this forum with great interest and learning quite a bit from the very knowledgable members here. I have done quite a bit reading about the wet stacking and am anxious to devise a...
  9. E

    MEP 003A Pre Start Inspection

    Stopped by the local NAPA and bought some filter bases from them and used wix filters. I replaced the fuel lines with some Parker Push-Lok hose and fittings from local hydraulic supplier. Pretty easy install.
  10. E

    pre lube pump for 002 genset

    Do a google search for ESP Pre-Luber. If you are looking for something off the shelf, they make nice stuff.
  11. E

    MEP 003A Pre Start Inspection

    Thanks Keith, will check out both units tomorrow.
  12. E

    MEP 003A Pre Start Inspection

    Just picked up a couple of MEP 003a's. I've given them the once over as suggested by the many fine contributers to SS. I've replaced all fuel lines with new, after installing new civvy spin on filters. The big question, I've read about some people having seized IP's. Can anyone give me a...