  1. C

    mep-002a fuel pumps qut running

    Thanks for the help swbradley1 I have read both these threads as well as several others that had some helpful information. I'm going over to my Dad's farm to work on this again today. I think I'm pointed in the right direction.
  2. C

    mep-002a fuel pumps qut running

    Would it automatically reset when reattached? Does it work by shutting down the fuel pumps when triggered? I am refering to a box with 2 latches on the bottom that is on the opposite side of the engine from the starter. It appears to contain glow plugs and/or block heater.
  3. C

    mep-002a fuel pumps qut running

    I thought maybe I had a bad breaker. When it popped the 15 amp I switched it back to the 7.5. After I reinstalled the 7.5 amp the fuel pumps were running. I disconnected a plug that goes into the bottom of the air box, and attempted to start it, the fuel pumps did not run but it cranked...
  4. C

    mep-002a fuel pumps qut running

    I have been trying to run down a short on a mep-002a that I just bought. It is popping cb when when in start position after roughly 5 seconds. I switched 15 amp from main electrical box with the 7.5 amp in control panel and it started and ran for 20 seconds then popped cb. I disconnected...
  5. C

    MEP 002 blowing DC breaker

    MidnightDuramax did you ever get this one to run? I'm having some similar problems and would like to know if you got it figured out. Thanks
  6. C

    Mep 003 converter frequency needed

    The Yokagawa is yc/24250anan I bought mine from peach state instruments in Marietta Ga. It is 2.5 inch (3 inch would be better). I don't know the number of the number of the Hoyt. http://www.battlegradeelectric.com/accessories.php
  7. C

    Calling all Generator Owners

    I found a replacement. Stant 10293
  8. C

    Mep 003 converter frequency needed

    Battlegrade Electric has one on his sight that looks like OEM it is just a 120 volt 55-65 analog meter like the Yokagawa. It is made by Hoyt in the USA and is pricey $200 or so. You can get the Yokagawa for under $100.
  9. C

    Mep 003 converter frequency needed

    Thanks. Do you know why the military chose the complicated expensive transducer and meter when a simple reliable inexpensive meter works fine? I assumed it was because the voltage on those wires changed with the voltage selector switch.
  10. C

    Mep 003 converter frequency needed

    Spedmon can you suggest a good place to hook up a 120 v freq meter in the control box. I was thinking about drilling a couple holes and hooking it to the convenience plug until I read this thread. Thanks
  11. C

    Calling all Generator Owners

    Don't know if this is the right place to ask this question. Does anyone know of a civilian replacement for radiator cap on MEP004A? And if this post is in wrong place let me know where to post question. Thanks for any help.