  1. Saunders

    MEP-803A trips breaker when load applied....Problem solved!

    Thought this might be worth sharing. My MEP-803A ran ok, but whenever I put a heavy load on it, the breaker would trip. Figured I'd try spraying the contacts on the S8 selector switch with some Deoxit cleaner and work the switch back and forth to clean any dirty contacts. When I took the top...
  2. Saunders

    MEP-802A voltage readings not right.

    Trying to help a friend get his recent auction purchase MEP-802A going. Looks mint condition with only 14hrs showing, but several cover screws missing indicating someone has been inside for some reason or another.Hoping someone may have ran into this before or can point me to in the right...
  3. Saunders

    Mep-003A Gen Head question

    Hello, I"m new to the forum here and had a question I hadn't seen addressed yet. I understand the Mep-003A has the ability to be switched and run to be either single or three phase. Is that simply because of the way it is wired to the VR or is the internal wiring in the gen head different...