• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

Search results

  1. storeman

    Need help 003a in previously perfect condition stopped producing power.

    Found the problem! My back has been bothering me so I apparently did not get low enough to see that I failed to reconnect J12 after I had moved it out of the way to cut the neutral to ground wire. All is well. Thanks for all your efforts in trying to help me. Good cheap birthday present...
  2. storeman

    Need help 003a in previously perfect condition stopped producing power.

    Munchies, I wish I did have another but will get to the troubleshooting suggestions after the weekend. Jerry
  3. storeman

    Need help 003a in previously perfect condition stopped producing power.

    Thanks to all. JBK (Jim) DC gauge is working. I haven't had time to follow through on the other recommendations, but will. Jimc, You may have just hit on it. As I recall, on that infamous day, I made a few other changes on my to-do list to comply with a long list of things I'd been noting...
  4. storeman

    Need help 003a in previously perfect condition stopped producing power.

    David, I'll try that as soon as possible. Wife has me all wrapped up in a 70th b-day celebration Saturday which I didn't ask for. I also can't visualize my actions on the battery disconnect switch doing any significant damage. Thanks. Jerry
  5. storeman

    Need help 003a in previously perfect condition stopped producing power.

    Ike, Was watching gauges and tried convenience plug after resetting it. I reset the main breaker but it shouldn't have impact on convenience plug. Did not try the lugs. All meters working before the incident. Thanks. Jerry
  6. storeman

    Need help 003a in previously perfect condition stopped producing power.

    Guys, Electronics is my admitted weak suit (among others). By way of background, I bought a laundry unit early this year which had been in storage and contained a mep-003A with only 54 original hours, 1991 model on a 1991 laundry unit. Generator ran like a dream until the day SS website went...
Top