  1. dmetalmiki

    M38A1 hard o start when cold

    Could be a weak spark, Those insulated leads tend to leak a bit when old. Check points gap and coil output via the king lead. (big fat spark? (jumps to ground?))' when craking each plug lead (off the plug) should have a good spark accross a 30 - 40 thou at least, 125 better!. to earth. check...