  1. F

    no start , i think some how i killed all the glow plugs and the resistor bank

    Assumed that .5 ohm is measured correct, the over all current in the glow plug system during jump start was I = U / R = 24V / (0.5 ohm resistor + 0.2 ohm all plugs) = 34 A The resistor reduced the voltage by 34 A * 0.5 ohm = 17 V The plugs saw the voltage 24 V - 17 V = 7 V So: current and...