  1. M

    Charging system

    check which battery is getting the 15V is it the upper or lower? upper is the one the 24V B+ cable goes to vehicle and its B- is connected to the lowers B+, the lower is the one whose B- is connected to chassis ground. if the lower one is 15V then swap the batteries around so it becomes the...
  2. M

    Charging system

    on the alternators manufactures website are troubleshooting guides for the alternator/Regulator, also the installation instructions. the website is "http://www.ceniehoff.com" the documents are under the Service and Support link at the top. N1225/N1387 Alternator Installation Instructions...