  1. Guyfang

    My MEP-803A

    This is one of the first things anyone does to the set. First take the wrench off the rope, and second, shorten the wrench a few inches. It's difficult for me to understand why the wrench is non conducting. Why, oh why, would anyone stick their hand down into that tiny little door, using a...
  2. Guyfang

    My MEP-803A

    Adjust the float, to cut off the aux pump right.
  3. Guyfang

    My MEP-803A

    Go to the A1, and measure what you have on the AC input to the A1, and what you have for the DC output to the M2. The freq meter takes its reading from the L3 and LO on the S8 switch. If you are not getting AC voltage from S8, then the Freq meter will not work. If you have AC from the S8 to the...
  4. Guyfang

    My MEP-803A

    Always ground the set before starting. If you don't do anything else, ground he set.
  5. Guyfang

    My MEP-803A

    Get the manuals. They are in the manual section of SS. Read troubleshooting, NO AC OUTPUT. But first fix the leaks. There are a number of threads, from DAYBREAK, that give you good info on what you need for service parts and antifreeze. Slow down. One step at a time partner. Lots of great info...