  1. J

    802 tripping overload

    Holy crap! I need to up my prices. I'm selling fully load tested units for $3,300 and I have one with 200hours on it for $4,000. :confused:
  2. J

    802 tripping overload

    So it sounds like working the switch has helped. So keep on that path, on some units I have to turn the switch back and forth at least 2-3 dozen times before it would act right.
  3. J

    802 tripping overload

    The indicator lights on the S7 (battle short) and S5 (Ac interrupter) are actually linked together on TB6-6 so a spike could have taken them both out. Look at R15 on the burden resistors because the battle short indicator DS6 goes through there. DS7 which is for the AC interrupter goes to K8...
  4. J

    802 tripping overload

    Yes, dirty or loose connections cause the safety system to overstate amperage. Trust us, we have all been there and thought it can't be a dirty connection but it normally turns out to be the connections. You can also try electrical cleaner from Wal-mart, that is what I use 90% of the time unless...
  5. J

    802 tripping overload

    If you getting your TM (technical manual) from this website, then there is a specific TM just for the wiring schematics which is what you need. You'll have to familiarize yourself with the codes of each item (i.e. S8 for the reconnection switch). After you have looked at the TM's a few times...
  6. J

    802 tripping overload

    Did you replace the connection board that had the mice nest on top, from one of you other threads? You're running 3 threads and its getting confusing; try to keep it to one and run off of that. So since the unit only has 15hours make sure all your wires on S8 and the av/vm (on the front panel)...
  7. J

    802 tripping overload

    Dirty connections on the reconnection switch are the problem 90% of the time. How many hours are on the unit?