• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

Search results

  1. Retiredwarhorses

    Non-op compressor

    pic of location?
  2. Retiredwarhorses

    Non-op compressor

    Compressor fixed...bad relay, multi-meter found no output when voltage applied, if I jumped it, it came on. $35 and all fixed...but it does not shut off now, so I’m looking for pressure switch wilspec 5200-189-0001 If I unplug the connector at the switch, it kills the pump.
  3. Retiredwarhorses

    Non-op compressor

    thank You, yes...seen that, Im a member on that forum
  4. Retiredwarhorses

    Non-op compressor

    perhaps I can just short the leads together to test...I’m assuming it’s a normally closed circuit, once it opens it kills the power to the relay, possibility it’s stuck open.
  5. Retiredwarhorses

    Non-op compressor

    So, I wired 24v to the compresso, it works...I get 24 volts to the fuse block, found the relay that the compressor switch goes too, it’s a 12v switch that activates the 24v relay. When the switch is activated, it kills the 12volts...I can hear and feel the relay opening and closing. I also get...
  6. Retiredwarhorses

    Non-op compressor

    Anyone done any TS on non-op compressor? I get voltage at the fuse block, nothing at compressor connector