  1. T

    Advanced Electrical Diagnostics Needed M1078

    Page 1135 is the symbols page followed by MANY pages of schematics. What are you seeing? I referred you to volume 3 so that seriesvof pages applies, but if you look in the back of other 20 series manuals you will find electrical schematic s too, as Ron pointed out. Maybe it would help us...
  2. T

    Advanced Electrical Diagnostics Needed M1078

    The electrical schematics are in the Manual TM 9-2320-365-20-3. Find this on this forum by looking in MANUALS, Present Conflict, second page from there, 8th line down, FMTV manuals then TM 9-2320-365-20-3. The schematic pages are near the bottom of the manual, around page 1134 and down. It...
  3. T

    Advanced Electrical Diagnostics Needed M1078

    When power is dropping out as you describe, start at the battery with a voltmeter and work your way toward the starter, and toward the Polarity Protection box and Power Distribution panel, looking for the point beyond which there is no DC voltage (applies to 12v and 24v circuits). Even though...