  1. Crash_AF

    M1008 will not turn over/crank

    If it's the wire I'm thinking about, it's a small orange wire from the control harness to the relay. The TM is wrong about where this wire goes, it is supposed to go on the glow plug side of the relay, not the resistor side. The TM has it backwards. Later, Joe