  1. I

    Slaveing with Genset??

    It is not designed to jump start, it is designed to charge the battery of a truck that is ran down, during cranking the starter probably draws several hundred amps. Think of it as a heavy duty gasoline powered battery charger, not another truck there to jump start from. Think of a motor pool...
  2. I

    Slaveing with Genset??

    Your MEP-026 outputs about 100 amps at 28V, as a general rule of thumb you should never try to charge a battery during bulk charging faster than about 1/5 of its capacity per hour. An 8D large truck battery is rated around 250AH at 12V, this means your MEP-026 should be able to charge 4 of...