  1. area52

    m816 starting issue

    If you put the fuel line after the filter in a 5 gallon can and it still did not start, then more than likely its your IP. There is a small filter inside the pump itself. There is a large flat screw on top that you unscrew and its a small metal filter.
  2. area52

    m816 starting issue

    try to pressurize the fuel tank with a very low air pressure (1 or 2 psi) and check the fuel lines for leaks. Air is probably getting in and causing the hard starts.