  1. m-35tom

    re-wiring my MEP-004a for different voltages, including single phase

    so why do you not have a schematic? they are free. http://igor.chudov.com/manuals/Military-Generators/MEP-004A/
  2. m-35tom

    re-wiring my MEP-004a for different voltages, including single phase

    yes i agree with this, but with this observation. the mil generators must be rated at the 120/240 configuration to begin with, and very under rated at that. i have to wonder about the 10 wire units like mep-805 and 806 that have 10, 11, 12 wire tied together internally. i will have to load test...
  3. m-35tom

    re-wiring my MEP-004a for different voltages, including single phase

    yes i realize that, but it is because the unit is grossly under rated to start with
  4. m-35tom

    re-wiring my MEP-004a for different voltages, including single phase

    while you can get 120/240 output easily, you can NEVER get full potential power output of the gen head. you will get 66% of rated because any way you rewire a 3 phase gen you are only having 2 coils in parallel not 3. the current is limited by the wire size in the gen. you might just as well...