Understood; wires for the load, and wires for sensing the generator output are indeed quite differnet things. Use of the word 'load' without mention of sensing threw me off.
14 Ga is a wee bit on the small side; I suggest something like a short flexible umbilical of water and oil proof cable 4 Ga. – 3 conductor to the plug and connector that feed into the transfer switch. For these short runs, think as heavy as you can make them and still be practical – because...
I suspect that it's not going to be completly straight forward to use one of these controllers on the MEP diesel set - because they were not intended to control a unit with the rather unique feature set of an MEP control box.
Now, don't get me wrong - you can make anything work with enough...