• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

Search results

  1. Guyfang

    MEP802A 3-Wire 240 Hookup Help

    True, and here, not always true. The "Classic Nullung" is still allowed. That is the distribution system that only has the phases and N at the house. In the plugs, there are wires that go from the N terminal, to the Ground terminal. It was allowed pre and post WW2 here in Germany, and several...
  2. Guyfang

    MEP802A 3-Wire 240 Hookup Help

    Yes. Here in Germany for instance, there are several different Distrabution systems. One type gets you all three phases and the N into the house fuse box. You drive a ground rod into the earth to provide ground to your fuse box. This the preferred method. Another system brings all three phases...
  3. Guyfang

    MEP802A 3-Wire 240 Hookup Help

    In the strictest sense, Ground and Neutral ARE the same.
  4. Guyfang

    MEP802A 3-Wire 240 Hookup Help

    Load terminals should be snug. No tighter. Chek them once a year. Don't just tighten them, loosen them and re-snug them. As mac wrote, over tightening will result in you buying a new terminal. The terminal is made of a copper alloy. Very easy to strip the threads.
Top
AdBlock Detected

We get it, advertisements are annoying!

Sure, ad-blocking software does a great job at blocking ads, but it also blocks useful features of our website like our supporting vendors. Their ads help keep Steel Soldiers going. Please consider disabling your ad blockers for the site. Thanks!

I've Disabled AdBlock
No Thanks