• Steel Soldiers now has a few new forums, read more about it at: New Munitions Forums!

  • Microsoft MSN, Live, Hotmail, Outlook email users may not be receiving emails. We are working to resolve this issue. Please add support@steelsoldiers.com to your trusted contacts.

Search results

  1. R

    Mep003a blowing resistor on bridge rectifier

    Issue resolved ! Changing out cvt1 seems to have done the trick. I can't thank Keith J and Speddmon enough for all their help! I would have had no idea of what to check. As a footnote, milbatteries.com has the adapter trays for converting 6tl's to the optima 34 for $14 each and will sell to...
  2. R

    Mep003a blowing resistor on bridge rectifier

    I received the cvt and linear reactor from Delks today and am hoping to do the install tomorrow. All I can find about the linear reactor in the tm says if there is physical damage, it should be replaced. The original one from my gen has a small crack in the top of the housing. The one I received...
  3. R

    Mep003a blowing resistor on bridge rectifier

    I ordered a new cvt1 transformer and linear reactor from Delk's today. I'll let everyone know how it turns out. Thanks for all the input and great advice
  4. R

    Mep003a blowing resistor on bridge rectifier

    I did some more checking today. The diodes on the bridge all test good. The M ohm readings occur when not using the diode test function. The meter voltage is too low that way. CT1 checks good. CVT1 has problems. All H connections test good but not the X connections. X1-X2 reads 39.1 ohms ...
  5. R

    Mep003a blowing resistor on bridge rectifier

    Thanks so much for the help! I will check the bridge board for problems again in the morning. Using the diode check function on my meter, I checked each individually before and got good checks. I was not really happy about the results I obtained according to table 6-6 so I will do it again...
  6. R

    Mep003a blowing resistor on bridge rectifier

    Thanks for the help Speddmon. I removed the blower housing to get access to the dc regulator. I unhooked the three wires and even pulled the fuse. Still on start up, the voltage pegs the meter at 300 when it was adjusted to 220. I attached the resistor on the bridge with alligator clips so I...
  7. R

    Mep003a blowing resistor on bridge rectifier

    Thanks for the insight Keith. I checked the voltage as you said. There was no voltage at connection 8 until I started to crank. When I released the start switch, voltage went back to zero as expected. This is where it gets weird. If I leave my meter connected and start the unit, I get battery...
  8. R

    Mep003a blowing resistor on bridge rectifier

    Hi all! im new to the site and am very impressed with the knowledge of the members. I'm having a problem with the resistor on the bridge assembly blowing on start up. I have been careful not to hold the start switch too long and the problem persists. Now for a little background. There is no...